Abstract:Ozonation and biological aerated filter (BAF)process as well as Fenton and BAF process were used to remove residual pollutants in coking wastewater treated by biological treatment system.Affecting factors including dosage of O3,pH value,molar ratio of Fe and H2O2,dosage of H2O2 and aeration time were studied.Results showed that when dosage of O3 was 800mg/L,aeration time of BAF was 18h or when dosage of H2O2 was 0.5mL/L,dosage of FeSO·47H2O was 2g/L,effluent COD was less than 70mg/L,color was less than 50 times,which met the Grade I of national emission standard.