Analysis of Clinical Stability of Ophthalmic Preparations Combined with Artificial Intelligence Medical Image Technology
Tangtang Jin,Gangze Fu,Lina Ge,Peizhen Lin
DOI: https://doi.org/10.1166/jmihi.2021.3342
2021-01-01
Journal of Medical Imaging and Health Informatics
Abstract:This study aims to analyze the stability of ophthalmic reagent cyclosporine polypeptide A and provide theoretical basis for future clinical medication. In this study, polyethylene glycol stearate with good physiological tolerance was selected to replace the emulsifier Tween80 in the sell prescription. The sell prescription was set as reagent 1, and the improved reagent was set as reagent 2. The two reagents were placed under high temperature (45 °C and 65 °C) and high light (4600Ix) for 18 days, and the pH and content of the two reagents were detected and recorded by artificial intelligence (AI) medical image segmentation technology based on Gabor wavelet function at 6 days, 12 days, and 18 days. Then, considering the actual storage problem of the reagent, the two reagents were placed in an environment (temperature of about 25 °C, relative humidity of about 60%, and protection from light) for 24 months. The pH and content of the two reagents were detected and recorded by hyperspectral images at 8, 16, and 24 months. The results showed that the pH value and content of the two reagents did not change significantly over time at 45 °C ( P > 0.05), and the pH and content of reagent 1 after 6 days at 65 °C were significantly less than the initial pH value ( P < 0.05). The pH and content of reagent 2 after 12 days were significantly lower than the initial pH value ( P < 0.05). Under strong illumination, the pH value and content of reagent 1 decreased with time, and there were significant differences ( P < 0.05). The pH value of reagent 2 showed no significant difference between 0 and 18 days ( P > 0.05), and the content was significantly lower than the initial content after 12 days of placement ( P < 0.05). The pH value and content of reagent 1 were significantly lower than the initial value after 16 months of storage ( P < 0.05). And the pH value and content of reagent 2 were significantly lower than the initial value when stored for 24 months ( P < 0.05). It showed that ophthalmic reagent cyclosporine polypeptide A is sensitive to high temperature and high light, and should avoid light and cool down during the transportation in hot season. Therefore, the adoption of polyethylene glycol stearate can effectively improve the stability of ophthalmic reagent cyclosporine polypeptide A, which has a high value in clinical application.