DETERMINATION OF PENICILLIN G IN PHARMACEUTICAL WASTEWATER BY SPE-RRLC-TANDEM MS

Li Zaixing,Zhang Feifei,Wang Yongjun,Chen Ping,Zhou Chonghui,Yu Xin
DOI: https://doi.org/10.7617/j.issn.1000-8942.2013.03.035
2013-01-01
Environmental engineering
Abstract:A method based on solid phase extraction-rapid resolution liquid chromatography-tandem mass spectrometry(SPERRLC-MS / MS) was developed to determine penicillin G in pharmaceutical wastewater.Water samples were firstly purified through protein precipitation processes with 30% zinc sulfate and 20% potassium ferrocyanide,and then the penicillin G was enriched and purified with Oasis HLB SPE,separated through Agilent Plus C 18 RRLC using 0.01 mol / L ammonium acetate solution(0.1% formic acid) and acetonitrile as mobile phase,and detected by mass spectrometry in positive ion mode with multiple reaction monitoring(MRM) using an electrospray ionization interface.The detection limit(S / N = 3) was 0.02 μg / L.The linear range was 0.0020mg / L to 1.0 mg / L,with a correlation coefficient of 0.9997.The recoveries at the spiked concentration of 0.20 μg / L,1.0 μg / L and 2.0 μg / L ranged from 74.6% to 101.4%,with a relative standard deviation from 4.49% to 8.17%.The procedure provides a rapid,reliable and sensitive method for determination of penicillin G in pharmaceutical wastewater.
What problem does this paper attempt to address?