Experimental Study of the Efficiency of Lithotripsy with Duplicate Pulses.

JZ Han,LL Liang,X Yang,B Li,SQ Gao,CG Huang,ZX Chen,YL Guo
DOI: https://doi.org/10.1089/089277903765444311
2003-01-01
Journal of Endourology
Abstract:BACKGROUND AND PURPOSE:Theoretical study had shown that compared with a single pulse, a duplicate pulse could improve the efficiency of lithotripsy. We conducted a series of studies to validate this idea.MATERIALS AND METHODS:The experimental study in vitro and in vivo used a lithotripsy machine with duplicate, single, and electromagnetic pulses.RESULTS:Use of a duplicate pulse improved the wastage of the model stones about 44.15% and the efficiency of lithotripsy about 44.76%. In pigs, the efficiency of lithotripsy was greater with a duplicate pulse than with single and electromagnetic pulses.CONCLUSION:Compared with single and electromagnetic pulses, duplicate pulses could improve the efficiency of lithotripsy by more than 40%.