1526: Changes in Hepatic Hemodynamics after Orthotopic Liver Transplantation: Long Term Observation with Color Doppler Ultrasonography

Hong Han,Wen-Ping Wang,Bei-Jian Huang,Hong Ding
DOI: https://doi.org/10.1016/j.ultrasmedbio.2009.06.913
IF: 3.694
2009-01-01
Ultrasound in Medicine & Biology
Abstract:ObjectiveTo analyze the hemodynamic changes with color Doppler flow imaging(CDFI) after orthotopic liver transplantation(OLT) during a long observation period (4 years).MethodsOne hundred forty-four patients with transplanted livers were included in the study. All patients were examined with ultrasound equipment PHILIPS-iU22 using a convex probe C2∼5MHz. The hemodynamic changes were measured and compared in 7 studied time points, including 1-day, 1-month, 6-months, 12-month, 18-month, 2-year, 3-year, 4-year after OLT.ResultsAfter liver transplantation, the hemodynamics of transplanted liver changed as follows: the peak systolic velocity of portal vein (PV-PSV) was high in the first day after operation, and decreased dramatically in 6-month after OLT, then a slowly decrease from 6-month to 18-month, reached a lower value(0.26±0.11)m/s at 18-month time point. A slowly decrease of arterial velocities was also showed over a long time period after OLT, at 3-year time point, the peak systolic velocity of hepatic artery(HA-PSV) was (0.48±0.20)m/s, which was lower than that measured in any other time point. The lowest resistance index of hepatic artery(HA-RI) was (0.69±0.10)measured at 1-month time point (p<.05), then it stabilized at a level of (0.71±0.09) at later studied time points. A total of 56% (81/144) of transplanted liver showed RI values greater than 0.8, while only 13% (19/144) showed less than 0.5.ConclusionsCDFI is valuable in evaluating hepatic hemodynamic changes after liver transplantation. ObjectiveTo analyze the hemodynamic changes with color Doppler flow imaging(CDFI) after orthotopic liver transplantation(OLT) during a long observation period (4 years). To analyze the hemodynamic changes with color Doppler flow imaging(CDFI) after orthotopic liver transplantation(OLT) during a long observation period (4 years). MethodsOne hundred forty-four patients with transplanted livers were included in the study. All patients were examined with ultrasound equipment PHILIPS-iU22 using a convex probe C2∼5MHz. The hemodynamic changes were measured and compared in 7 studied time points, including 1-day, 1-month, 6-months, 12-month, 18-month, 2-year, 3-year, 4-year after OLT. One hundred forty-four patients with transplanted livers were included in the study. All patients were examined with ultrasound equipment PHILIPS-iU22 using a convex probe C2∼5MHz. The hemodynamic changes were measured and compared in 7 studied time points, including 1-day, 1-month, 6-months, 12-month, 18-month, 2-year, 3-year, 4-year after OLT. ResultsAfter liver transplantation, the hemodynamics of transplanted liver changed as follows: the peak systolic velocity of portal vein (PV-PSV) was high in the first day after operation, and decreased dramatically in 6-month after OLT, then a slowly decrease from 6-month to 18-month, reached a lower value(0.26±0.11)m/s at 18-month time point. A slowly decrease of arterial velocities was also showed over a long time period after OLT, at 3-year time point, the peak systolic velocity of hepatic artery(HA-PSV) was (0.48±0.20)m/s, which was lower than that measured in any other time point. The lowest resistance index of hepatic artery(HA-RI) was (0.69±0.10)measured at 1-month time point (p<.05), then it stabilized at a level of (0.71±0.09) at later studied time points. A total of 56% (81/144) of transplanted liver showed RI values greater than 0.8, while only 13% (19/144) showed less than 0.5. After liver transplantation, the hemodynamics of transplanted liver changed as follows: the peak systolic velocity of portal vein (PV-PSV) was high in the first day after operation, and decreased dramatically in 6-month after OLT, then a slowly decrease from 6-month to 18-month, reached a lower value(0.26±0.11)m/s at 18-month time point. A slowly decrease of arterial velocities was also showed over a long time period after OLT, at 3-year time point, the peak systolic velocity of hepatic artery(HA-PSV) was (0.48±0.20)m/s, which was lower than that measured in any other time point. The lowest resistance index of hepatic artery(HA-RI) was (0.69±0.10)measured at 1-month time point (p<.05), then it stabilized at a level of (0.71±0.09) at later studied time points. A total of 56% (81/144) of transplanted liver showed RI values greater than 0.8, while only 13% (19/144) showed less than 0.5. ConclusionsCDFI is valuable in evaluating hepatic hemodynamic changes after liver transplantation. CDFI is valuable in evaluating hepatic hemodynamic changes after liver transplantation.
What problem does this paper attempt to address?