Chemiluminescence Analysis of Menadione Sodium Bisulfite and Analgin in Pharmaceutical Preparations and Biological Fluids
YM Huang,C Zhang,XR Zhang,ZJ Zhang
DOI: https://doi.org/10.1016/s0731-7085(99)00191-0
IF: 3.571
1999-01-01
Journal of Pharmaceutical and Biomedical Analysis
Abstract:A novel chemiluminescence (CL) flow system for two sulfite-containing drugs, namely, menadione sodium bisulfite (MSB) and analgin is described. It is based on the weak chemiluminescence induced by the oxidation of sulfite group in drugs with dissolved oxygen in the presence of acidic Rh6G. Tween 80 surfactant micelles showed a strong enhancement effect on this weak chemiluminescence. For MSB analysis, online conversion of MSB in alkaline medium into sodium bisulfite was necessary, whereas analgin could be determined directly. The proposed method allowed the measurement of 0.05-50 microg/ml(-1) MSB and 0.05-10 microg/ml(-1) analgin. The limits of detection (3sigma) were 0.01 microg/ml(-1) MSB and 0.003 microg/ml(-1) analgin. The method was applied satisfactorily to pharmaceutical preparations as well as biological fluids.