Clinical use of removable partial dentures of Vitallium 2000 casting frame

Liu Yang,Li Zhen-chun,Chen Xiao-dong
DOI: https://doi.org/10.3969/j.issn.1673-8225.2011.29.041
2011-01-01
Abstract:BACKGROUND: As late introduction to China, Vitallium 2000 has been rarely reported. OBJECTIVE: To observe the clinic effect of Vitallium 2000 as framework material in removable partial denture. METHODS: Eighty-six Vitallium 2000 framework removable partial dentures were used for 67 patients, clinical examination were carried out from 1 to 2 years, and the condition of abutment and the performance of dentures were recorded based on self-evaluation and intraoral examination. RESULTS AND CONCLUSION: The removable partial dentures with Vitallium 2000 framework are comfortable and good as well as its masticatory function and retention, and they especially can be designed for some free-end clinical cases. In the study, one case of repeated tenderness underwent re-produced denture, and the artificial tooth and denture base had a good bite force; in 6 months and 1 year re-examination, a total of three cases presented with abutment periodontitis, and they were all recovered at 2 months following periodontal treatment. Vitallium 2000 framework removable partial dentures have a good clinical effect.