Selection of coagulant for treatment of raw water with low temperature and low turbidity from Luanhe River

Li Aibin,Fu Chunming,Wang Jin
DOI: https://doi.org/10.3969/j.issn.1673-9353.2011.04.003
2011-01-01
Abstract:Treatment efficiencies of raw water from Luanhe River under various dosages of coagulants were investigated with FeCl3,FeCl3 mixing solution and polyaluminum chloride(PAC).The results showed that best removal of turbidity and CODMn could be obtained with mixed addition of FeCl3 mixing solution and PAC.The optimal dosages were 10 mg/L FeCl3 mixing solution(iron and sodium silicate volume ratio of 1:1) and 2.5 mg/L PAC,and the chemical cost was 0.013 1 Yuan/m3.The dosage of 10 mg/L FeCl3 mixing solution(iron and sodium silicate volume ratio of 1:2.0) was used if the optimal mixed dosage method could not be utilized.The dosage could be suitably adjusted according to the variation of water quality in practical operation of waterworks.
What problem does this paper attempt to address?