Numerical Simulation and Optimazition Design for Cone Differential Pressure Flowsensor

XU Ying,YANG Hui-feng,WU Jing-wei,LI Gang,WANG Hua-xiang
DOI: https://doi.org/10.3969/j.issn.1671-4776.2007.07.002
2007-01-01
Abstract:Computational fluid dynamics(CFD) numerical simulation tests for cone differential flowsensors with diameter of 100 mm were carried out by RNG k-e turbulence model,and the va-lues of equivalent diameter ratio β,are 0.50,0.65,0.85 respectively,overall 27 sorts of combinations were done,the fore V-cone angle are 40°,45°,50° respectively,the aft V-cone angle are 120°,130°,140° respectively.The simulation results show that the discharge coefficient increases while the β is decreased,and it is influenced more easily by Reynolds number while the β is increased.If the β keeps the same value,the fore cone angle is crucial.Larger fore cone angle will weaken the influence of the Reynolds number.
What problem does this paper attempt to address?