Simulation Study on MEMS V-cone Sensor in Hydraulic System

Zhang Hongpeng,Gu Changzhi,Zhang Xingming,Chen Haiquan,Liu Dong,Zhang Yindong,Shen Yan
DOI: https://doi.org/10.3724/sp.j.1187.2012.00419
2013-01-01
Abstract:In the hydraulic system,because of the characteristics of hydraulic drive and the limitation of the hydrau-lic oil,it is hard to find an ideal dynamic measurement instrument in the process for flow measurement today.In order to improve this situation,on the basis of research on hydraulic flow measurement applied the pressure gradient method,combined the advanced MEMS technique with the traditional V cone flow sensor,a new method which obtained the dif-ferential pressure signals directly in the pipe to measure the flow was proposed.Then the differential pressure-velocity model was deduced,and the influence on flow field caused by key parameters(the fore cone angle θ and the equivalent diameter ratio β) of V cone was simulated by Fluent.The simulation results show that the best value range of the fore cone angle is 45°~60°,the best value range of the equivalent diameter ratio is 0.75~0.85.