Numerical Simulation for Cone Style Differential Pressure Flowsensor
XU Ying,WU Jing-wei,ZHANG Qiang,LI Gang,LI Qiao-zhen
DOI: https://doi.org/10.3969/j.issn.1004-1699.2007.10.044
2007-01-01
Abstract:Computational fluid dynamics (CFD) numerical simulation tests for cone differential flowsensors with diameter of 100 mm are carried out here, which RNG k-ε turbulence model is used and the values of equivalent diameter ratio, viz. β, are 0.50, 0.65, 0.85 respectively, the fore Cone angle, 40°, 45°, 50° respectively, the aft V-Cone angle, 120°, 130°, 140° respectively. The simulation results show that the discharge coefficient increases while the β is decreased, and it is influenced more easily by Reynolds number while the β is increased. Secondly, if the β keeps the same value, the fore Cone angle is crucial, and the aft can influence the linearity at a certain extent. Thirdly, larger fore Cone angle will weaken the influence of the Reynolds number. Comparison with real physical tests, the averaged deviation of simulations is approximate 5%, the maximum, less than 9.1%.