PIV measurements used for the flow field of the physical model of magnesium electrolyzer

MU Lei,LI Bing,SUN Ze,SHU Zhong-ming,YU Jian-guo
DOI: https://doi.org/10.13662/j.cnki.qjs.2010.04.007
2010-01-01
Abstract:A physical model cell was built according to the geometry similarity to an industrial magnesium electrolyzer structure at high temperature.In the physical model cell,the two-phase flow consisted of oxygen produced at anode in electrowinning of a zinc sulfate solution and the solution flow induced by oxygen was used to simulate the flow behavior of chlorine and electrolyte and liquid magnesium(simplified to gas-liquid two-phase flow) in a industrial magnesium electrolyzer.And a particle image velocimetry(PIV) was employed to characterize the fluid flows of the physical model cell,and the effects of the anode-cathode distance,the distance between the partition wall and electrode and the anode immersion depth were examined.The results showed that the anode-cathode distance(ACD) and the distance between the partition wall and electrode(W) played significant effects on the flow field,and the anode immersion depth(D) had little effects on it.The optimized cell structure was suggested as ACD =2cm,W =0.7cm and D=11.5cm.