Research on emergency treatment of accidental phenol pollution of drinking source water by adsorption-oxidation process

Wang Xingang,Liu Xueqing,Chen Fangyan,Tang Yubin,Lü Xiwu,Zhang Dong,Zhou Xinyu
2011-01-01
Abstract:Against the background of accidental phenol pollution occurred in water head site situated at upstream of Huangpu River,the removal efficiencies of the adsorption of phenol by powdered activated carbon(PAC) adsorption,potassium permanganate oxidation and the two combination techniques were mainly investigated.The results showed that the choice of activated carbon and oxidizing agent was the significant factor to affect phenol removal rate.The phenol removal by bamboo charcoal with abundant micropores and large specific surface area is obviously better than that by coal-based,coconut shell-based or ligneous-based PAC.The oxidation capacity of potassium permanganate to phenol is better than sodium hypochlorite or potassium ferrate.The phenol removal rate can be effectively increased via raising PAC and potassium permanganate dosage.PAC adsorption coupled with potassium permanganate oxidation could significantly improve the removal efficiency of phenol.Using 50 mg/L PAC combined with 2 mg/L potassium permanganate,phenol content in polluted raw water could be decreased from initial concentration of 250 μg/L and 500 μg/L to 18 μg/L and 66 μg/L,respectively.PAC adsorption coupled with potassium permanganate oxidation process is an effective emergency measure to deal with high concentration phenol pollution.