Analysis of an Air Powered Engine System Using a Multi-Stage Radial Turbine.

Xuehui Zhang,Haisheng Chen,Xiaohui Yan,Xinjing Zhang,Chunqing Tan
DOI: https://doi.org/10.3390/e15041186
IF: 2.738
2013-01-01
Entropy
Abstract:The performance and design criteria of air powered multistage turbines are studied thermodynamically in this paper. In-house code is developed in the C++ environment and the characteristics of four-stage turbines with inter-heating are analyzed in terms of maximum thermal efficiency, maximum exergy efficiency and maximum work output over the inlet temperature range of 293 K–793 K with inlet pressure of 70 bar. It is found that the maximum thermal efficiency, maximum exergy efficiency and maximum work output are 62.6%, 91.9%, 763.2 kJ/s, respectively. However, the thermal efficiency, exergy efficiency and work output are not equivalent for the four-stage radial turbine. It is suggested that at low working temperatures both maximum exergy efficiency and maximum work output can be used as the design objective, however, only maximum work output can be used as the design objective for the four-stage radial turbine over the working temperature range in this work.
What problem does this paper attempt to address?