Effect of Section Shape for Cooling Channel in Copper Cooling Stave of Blast Furnace

ZONG Yan-bing,MO Zhi-ying,CHENG Xiang-li,GUO Fa-jun,CANG Da-qiang,SHE Jing-peng,WU Qi-chang
DOI: https://doi.org/10.3321/j.issn:1001-0963.2005.06.004
2005-01-01
Abstract:The methods of optimizing the design of the section of copper stave′s cooling channels were proposed based on the theory of heat transfer.The results of the 1∶1 hot simulation test show that the relation between the heat and the shape of the cooling channels is as follows: Q∞CA~(0.1).The optimized cooling channels can lower the amount of cooling water to 24% and reduce the thickness of the stave to 20 mm.What's more,the developed prolate channels can meet the purpose of improving the heat transfer.