Mechanism of local amplification in attenuation of ground vibration induced by rail traffic
Xin ZHENG,Xia-xin TAO,Fu-tong WANG,Li-li XIE
DOI: https://doi.org/10.3969/j.issn.1000-3835.2014.03.009
2014-01-01
Abstract:In order to investigate the forming mechanism of local amplification in rail traffic-induced ground vibration attenuation,the ground was simplified to be a single soil layer covering on an elastic half-space.Dynamic Green's function of vertical ground displacement of a three-dimensional layered site model was derived in frequency domain.The effects of many fators including seven modulus ratios of half space to covering layer,four thicknesses of convering layer,seven exciting frequencies,and three damping ratios of convering layer on local amplification were analyzed.The results showed that local amplification is controlled by an important buried velocity interface,its location and intensity of amplification depend on ratio of elastic moduli of medias in the both sides of the interface,i.e., impedance ratio,thickness of covering layer,exciting frequency and damping ratio of covering;in general,the larger the impedance of the interface,the stronger the local amplification;giving the other conditions,the closer the directly arriving time of surface wave and the arriving time of refraction wave from the interface which are governed by covering layer thickness,the more obvious the local amplification;the closer the peaks of waves which are governed by exciting frequency,the more obvious the local amplification;the smaller the damping ratio of covering layer,the stronger the local amplification.