Behaviour of Concrete Filled Steel Tubular (cfst) Stub Columns under Eccentric Partial Compression

You-Fu Yang,Lin-Hai Han
DOI: https://doi.org/10.1016/j.tws.2010.09.024
IF: 5.881
2011-01-01
Thin-Walled Structures
Abstract:This paper investigates the behaviour of concrete filled steel tubular (CFST) stub columns subjected to eccentric partial compression. Twenty-eight specimens were tested and presented. The main parameters in test program include: (1) section type: circular, square and rectangular; (2) load eccentricity ratio (including uniaxial and biaxial loading): from 0 to 0.4; and (3) shape of the loading bearing plate (BP): circular, square, strip and rectangular. The test results indicated that, similar to the corresponding fully loaded CFST stub columns under eccentric loading, CFST stub columns under eccentric partial compression have generally reasonable bearing capacity and favorable ductility. A finite element analysis (FEA) model for CFST stub columns under eccentric partial compression is developed and the predicted performances are validated through measured results. The FEA model is then used to investigate the mechanisms of such composite columns further.
What problem does this paper attempt to address?