Chemiluminescence of Potassium Permanganate–Glyoxal–Sulfur Contained Compound System

Guangbin Zhang,Yuhai Tang,Haiyan Li,Hongling Yu,Sijuan Sun
DOI: https://doi.org/10.1080/00032710802586921
2009-01-01
Analytical Letters
Abstract:Sulfur contained compound (SCC) had different abilities in term of increasing the intensity of chemiluminescence of potassium permanganate with glyoxal. In a flow system, including methimazole, captopril, cimetidine, methionine, chloropromazine hydrochloride, chlorprothixene and propacil, enhanced intensity was detected, therefore the CL of potassium permanganate-glyoxal-SCC system was studied. Under the optimized experimental conditions, low detection limit and large calibration ranges for Sulfur contained compound were obtained. The proposed method allowed 90 injections h-1 with excellent repeatability and precision. The method was successfully applied to the determination of six SCC in commercial pharmaceutical formulations with recoveries in the range of 97.24-102.2%. The method was validated through the pharmacopoeia reference method. The possible chemiluminescence reaction mechanism of potassium permanganate-glyoxal-SCC was discussed briefly.
What problem does this paper attempt to address?