Enhanced chemiluminescence of carminic acid-permanganate by CdS quantum dots and its application for sensitive quenchometric flow injection assays of cloxacillin

Alireza Khataee,Aliyeh Hasanzadeh,Roya Lotfi,Sang Woo Joo
DOI: https://doi.org/10.1016/j.talanta.2016.01.055
IF: 6.1
2016-05-15
Talanta
Abstract:A novel chemiluminescence (CL) system is introduced based on the oxidation of carminic acid by KMnO4 in acidic conditions. CdS quantum dots (QDs) were synthesized using a facile hydrothermal method which efficiently enhanced the intensity of the CL system. A possible mechanism for the proposed system is presented using the kinetic curves, CL spectra, photoluminescence (PL), and ultraviolet-visible (UV-Vis) analysis. The emission intensity of the KMnO4-carminic acid-CdS QDs system was quenched in the presence of a trace level of cloxacillin. Based on this quenching effect, a novel and sensitive flow injection CL method was developed for determining cloxacillin concentrations. At optimal experimental conditions, the decreased CL intensity had a good linear relation with the cloxacillin concentration in the range of 0.008 to 22.0 mg L(-1). The detection limit (3σ) was 5.8 µg L(-1). The precision of the method was calculated by analyzing samples containing 4.0 mg L(-1) of cloxacillin (n=11), and the relative standard deviations (RSD%) were 2.08%. The feasibility of the method is also demonstrated for determining cloxacillin concentrations in environmental water samples and a pharmaceutical formulation.