Fracture strengths of domestic ceramic orthodontic brackets during mesial-distal archwire tipping

YANG Li,FENG Ping-ping,BAI Yu-xing,WANG Bang-kang,XIE Zhi-peng,QIN Xiao-tong
DOI: https://doi.org/10.3969/j.issn.1006-673x.2007.04.006
2007-01-01
Abstract:Objective To evaluate the fracture strengths of the domestic polycrystalline alumina orthodontic brackets developed by the authors during mesial-distal archwire tipping.Methods The fracture force and moment of domestic ceramic brackets during mesial-distal arch wire tipping of the domestic polycrystalline alumina orthodontic brackets were measured by using the special device developed also by the authors. Crystaline IV bracket, which was commonly used in clinic, served as control.Results The fracture force and moment of domestic ceramic brackets during mesial-distal arch wire tipping were (4159.3±881.8) gm and (16179.8±3430.2) gm-mm. There were no significant differences in fracture force and moment between the two types of brackets.Conclusion The fracture strength of domestic ceramic brackets during mesial-distal archwire tipping can meet the reqirements of clinical orthodontic treatment.