Design and Test of Large Span-to-height Ratio and Large Span RC Floor Beams

Zhao Yiqiang,Ke Changhua,Cheng Maokun,Qian Jiaru,Zhao Zuozhou,Huang Xiaokun,Liu Weimin,Liu Zheng
2008-01-01
Abstract:To satisfy the clear height requirement,the span-to-height ratios of 20.4 and 22.7 were adopted for the simply supported reinforced concrete secondary floor beams with span of 12.245m and 10.225m respectively for tower A and B of Beijing Goldfield Center.The design of these large span-to-height ratio and large span secondary floor beams is presented.To study the behavior of the secondary beams under the serviceability limit state,field test of a full scale specimen was carried out and calculation was performed according to design codes.The results show that both crack width and vertical deflection can meet the code requirements.Based on the test results,recommendations are presented for design and construction.The structures of tower A and B have been completed and no obvious cracks on the secondary floor beams have been found.
What problem does this paper attempt to address?