Thermodynamic check calculation for the turboset of CEFR

ZHANG Qian,LU Yun,ZHANG Dong-hui,WU Qiang
DOI: https://doi.org/10.3969/j.issn.0258-0918.2013.01.006
IF: 1.2
2013-01-01
Nuclear Science and Engineering
Abstract:CEFR is the first sodium coolant fast reactor in China.The main function of the three loops is to transform the heat energy from the nuclear island to electricity energy.The turboset has completed three auxiliary steam impact tests and the grid-connected power generation test in 40%P0 working condition after installed and commissioned,but its rated power thermodynamic performance cannot be demonstrated at all times.By thermodynamic check calculation,this paper demonstrates that its capacity at rated power and gets its thermal economics.It also provides significant reference for the whole plant thermal equilibrium calculation of CEFR.
What problem does this paper attempt to address?