Determination Of Helicidum And Its Metabolites In Dog Plasma By Lc/Uv/Ms/Ms And Its Application To Pharmacokinetic Studies

Qf Liu,Xd Liu,G Luo,Ww Tian,Ym Wang
DOI: https://doi.org/10.1016/j.jchromb.2005.12.042
2006-01-01
Abstract:A simple, rapid and reliable method was developed for the identification and quantification of helicidum and its metabolites in beagle dog plasma by liquid chromatography/ultra-violet/electrospray ionization-ion trap mass spectrometry (LC/UV/ESI-ITMS). Two metabolites were identified by MS: formylphenyl-O-beta-D-pyranosyl alloside (I) and hydroxylmethylphenyl-O-beta-D-pyranosyl alloside (II). UV was used for concentration determination with the wavelength of 270 nm. Liquid-liquid extraction was used and the extraction recovery exceeded 90%. Kromacil C-18 column (5 mu m, 4.6 mm i.d. x 250 mm) was used as the analytical column. Linear detection responses were obtained for helicidum concentration ranging from 1.76 x 10(-4) to 70.4 x 10(-4) mu mol/mL (0.050-2.00 mu g/mL). The precision and accuracy data, based on intra- and inter-day variations over 3 days. were less than 5%. The limit of determination and quantitation (LOD, LOQ) for helicidum was 0.010 and 0.030 mu g/mL, respectively. Pharmacokinetic data of helicidum and dthe two metabolites were obtained with this method after administration of intravenous injection and a single oral dose of tablets to six beagle dogs, respectively. (c) 2006 Published by Elsevier B.V.