Determination of arbidol in rat plasma by HPLC-UV using cloud-point extraction.

Xiao Liu,Xiao-Hui Chen,Yuan-Yuan Zhang,Wen-Tao Liu,Kai-Shun Bi
DOI: https://doi.org/10.1016/j.jchromb.2007.06.009
IF: 3.318
2007-01-01
Journal of Chromatography B
Abstract:A method based on cloud-point extraction (CPE) was developed to determine arbidol in rat plasma by high performance liquid chromatography separation and ultraviolet detection (HPLC–UV). The non-ionic surfactant Triton X-114 was chosen as the extract solvent. Variable parameters affecting the CPE efficiency were evaluated and optimized. A Zorbax SB-C18 column (4.6mm i.d.×150mm, 5μm particle size) was used for isocratic elution separation at 40°C with detection wavelength at 316nm. Under the optimum conditions, the method was shown to be reproducible and reliable with intraday precision below 6.6%, interday precision below 8.8%, accuracy within ±5.0% and mean extraction recovery more than 89.7%, which were all calculated using a range of spiked samples at three concentrations of 0.2, 2 and 16μg/ml for arbidol in plasma. The linear range was from 0.08 to 20μg/ml. After strict validation, the method was successfully applied to the pharmacokinetic study of arbidol in rats after oral and intravenous administration, respectively.