Regulation of the distribution between pulmonary and systemic flow after blalock-taussig shunt operation

LI Zhi-hao,XU Zhi-wei,ZHANG Hai-bo,ZHENG Jing-hao,SHI Zhen-ying,XU Zhuo-ming
DOI: https://doi.org/10.3877/cma.j.issn.1674-0785.2012.22.026
2012-01-01
Abstract:Objective Searching an optimal balance between pulmonary and systemic flow through ventilator parameter adjustment and inotropic agents titration after Blalock-Taussig shunt,in order to improve its survival rate.Methods Summarize a consecutive series of 57 cases who received Blalock-Taussig shunt between July.1st,2011 and June.30th,2012.Regulated ventilator parameter to control the gas-check outcome,making PCO2 in 50-55 mm Hg;pH:7.30-7.35.Inducing light respiratory acidosis to elevate the pulmonary resistance to limit pulmonary flow;control the inspired oxygen concentration to make transcutaneous oxygen saturation maintain between 70%-80%.Meanwhile,using a little dose of vasodilator agents(such as milrinone and nitroprusside)to decrease systemic resistance to improve body perfusion.Results 13 cases died,mortality was 22.8%.In emergency cases,5 died,mortality 35.7%,in selective surgery cases,8 died,mortality 18.6%.The mortality is the same in patients suffered patent arterial duct whether their duct was ligated or not.Conclusions Suitable adjustment of pulmonary and systemic flow ratio is the key point in intensive care after Blalock-Taussig shunt.Depending on pulmonary resistance regulation may exist potential risk,whereas combined with systemic flow regulation may present a better outcome.