Central Aorto-Pulmonary Shunts in the Tetralogy of Fallot

高文根,张仁福,汪曾炜,朱洪玉,王军,韩宏光
DOI: https://doi.org/10.3760/cma.j.issn.1001-4497.2004.06.002
2004-01-01
Abstract:Objective To evaluate the surgical results of central aorto-pulmonary shunts in the tetralogy of Fallot. Methods Between January 1998 and December 2003, 24 patients with tetralogy of Fallot, 16 males and 8 females, with age from 7 months to 19 years [mean (5.3±4.6) years] and weight from 6.5 kg to 45.0 kg [mean (16.9±9.7)kg], were studied. Central aorto-pulmonary shunts were performed with Teflon artificial blood vessels in 10 cases and varicosity Teflon artificial blood vessels (Gore-Tex) in 14 cases. The diameter of these vessels was 3 mm to 6 mm. Results Ideal pulmonary flow in each patient was obtained. The mean SaO 2 stepped up from 0.67±0.09 to 0.93±0.04 after operation (P0.01). There were two postoperative deaths (2/24,8.3%). Two-stage radical operations were performed in 14 patients, and one patient died after operation. In two-stage radical operation, the diameter of pulmonary artery increased 60.5% and EDVI increased 57.4% as compared to the first operation. Conclusion Central aorto-pulmonary shunt is effective in improving patient's conditions and is a preparatory measure for a satisfactory staging operation in severe tetralogy of Fallot.