Experiment on Tip Flow Property of High Speed Axial Flow Compressor

AO Yong-ping,SHAN Zhi-chao,HE Yi-na,XIONG Bing,FAN Jia-feng
DOI: https://doi.org/10.3969/j.issn.1672-2620.2013.04.003
2013-01-01
Abstract:To investigate compressor tip flow property,the wall static pressure of its 1th rotor was measured using high frequency dynamic pressure sensors.The phase average method was employed to analyze the test data collected at different corrected speeds.The analysis results show that the shock wave in channel is in evidence when the relative corrected speed is above 0.6 and the strength of shock wave increases with the compressor speed.The leakage flow is clear and strong at the leading edge and it weakens along with the flow direction,affecting the nearly 1/2 length of chord and 1/3 of cascade channel flowfield.The fluctuating pressure Vp-p is largest about 15~20 kPa at the 1/3 length of chord when the speed is above 0.7 which will bring about aerodynamic excitation and the blade will undertake large periodic aerodynamic load.
What problem does this paper attempt to address?