Vibration Analysis of Generator Floor Slab of Shuikou Hydroelectric Station

CHEN Shuai,ZHANG Zhenhua,LUO Xianqi,HAN Yong
2010-01-01
Abstract:The vibration characteristics of generator floor slab of Shuikou hydroelectric station are analyzed by setting up three-dimensional finite element model.The vibration property of power house is studied and its resonance checking is conducted.The vibration response of all quadrants and generator piers of generator floor slab are analyzed under the action of mechanical vibration loads and pressure pulsation in spiral case.The corresponding time-history analysis is carried out under the strong response load.The results show that the generator floor slabs do not appear resonance;all quadrants of floor slabs response strongly under pulse pressure in spiral case;it appears strong response around generator piers under mechanical vibration loads;the magnification of vibration response is closed to 10 times in some areas of floor slabs;some vibration response values are beyond allowed range;in order to ensure the normal operation of generator units,it should avoid appearing adverse frequency and enhance monitoring and early warning in this area.