Determination of bisphenol A in canned foods by high performance liquid chromatography

PENG Qing-zhi,PAN Si-yi,LIU Song
2010-01-01
Abstract:Objective:To set up the analysis methods of Bisphenol A residue in Canned food by HPLC.Methods: Bisphenol A in sample was extracted by acetonitrile after fat and protein were took out,chromatogram conditions were folowing: Global chromatography C18 column,mixture of acetonitrile-0.02 mol/L ammonium acetate was used as the mobile phase under fluorescence detector with excitation and emission wavelengths of 228 nm and 310 nm,espectively.Results: The recoveries were 85.1%~105.0% for canned drink and 81.2%~93.9% for canned meat,relative standard deviations were 3.1% and 4.9 %(n=5) respectively and detection limit was 1.2 μg/L.Conclusion: The method is simple,rapid,sensitive,accurate and suitable for determination of canned foods.
What problem does this paper attempt to address?