Determination of Procaine Hydrochloride in Procaine Hydrochloride Injection by Micro Total Analysis System

CAI Zi-you,LI Yong-chong,YE Bin,CHEN Zuan-guang
DOI: https://doi.org/10.3969/j.issn.0367-6358.2011.01.005
2011-01-01
Chemistry World
Abstract:A new rapid method was established for the determination of the active component in procaine hydrochloride injection by micro total analysis system with contactless conductivity detection.The electrophoretic parameters,such as the variety and concentration of buffer solution and additive,separation voltage and injection time and etc,were optimized.Procaine hydrochloride(PH)was separated and detected within 2 min in the buffer of 1 mmol / L HAc + 3 mmol / L NaAc(pH 4.5) with 0.08 mmol / L SDS at the separation voltage of 2.20 kV and injection for 10s.The linear concentration of PH ranged from 20 μg / mL to 250 μg / mL(r~(2)= 0.998),and the limit of detection(LOD) reached 5.0 μg / mL(S/N=3).The RSD was 1.8% and the recoveries ranged from 98.4% to 99.0%.
What problem does this paper attempt to address?