Abstract:This paper describes a pump limiter experiment in the HL-1 Tokamak. The pump limiter consists of a single-throat head covered by graphite tiles, a stainless steel neutralizer plate and a limiter chamber and it is pumped by a 1500 1 s-1 turbomolecular pump.The experimental results showed that the exhaust efficiency epsilon of the pump limiter for particles of the scrape-off-layer (SOL) was about 0.07 and the pump limiter was capable of exhausting helium ash from the enhanced H-alpha line and HeI line emissions in the vicinity of the neutralizer plate in H2 (60%) + He(40%) mixture gas discharges. Compared with the discharges without a pump limiter, the recycling coefficient R decreased about 20% (when nBAR(e) approximately 3-4 x 10(13) cm-3), and the particle confinement time tau-p increased about 18%. The average heat load measured over the graphite limiter head was about 250 W cm-2 in normal discharges. The non-symmetric distributions of the heat load in toroidal and poloidal directions were also observed.