Application of tension-free hernioplasty in sliding hernia

WANG Qingtao,ZHOU Yi,LIN Qimou
DOI: https://doi.org/10.3969/j.issn.1009-976X.2007.02.016
2007-01-01
Abstract:Objective To evaluate the therapeutic effect of tension-free hernioplasty on sliding hernia and go further into the applied indication,anatomic basis and some points for attention during the operation. Methods From January 2002 to December 2004, eight cases with sliding hernia received Mesh Plug ﹠patch or polypropylene prolene hernia system(PPHS)in tension-free hernioplasty were analyzed retrospectively. Results Excepting for 1 case had postoperative slight subcutaneous hematoma and no postoperative complication were found in other 7 cases. All patients were discharged from hospital at the seventh or tenth day after operation. Postoperative follow-up time was from 8 to 20 months and no recurrence was found. Conclusions Both PPHS and Mesh Plug ﹠patch in tension-free inguinal hernia repair are ideal materials for sliding hernia. According to the patients concrete condition to select individualized operative project, it can improve the surgical therapeutic effects.