Mesh Infection in Tension-free Hernioplasty

TANG Li-ming,FEI Xiao-zhou,SUN Yi-feng,MA Yu-liang,WANG Guo-hua,HUANG Hong-liang
DOI: https://doi.org/10.3877/cma.j.issn.1674-392X.2013.02.024
2013-01-01
Abstract:Objective To evaluate the prevention and treatment of prosthetic mesh infections in tension-free hernioplasty.Methods The clinical date of 7 incision infections admitted from January 2009 to July 2012 were analyzed retrospectively.3 cases were repaired by a bilayer mesh(Prolene Hernia System).1 case was repaired with Mesh plug and 3 cases were repaired with an onlay mesh.As for the material used there were flat knitted polypropylene in 5 cases,polytef in 1 case and polyester in 1 case.Treatments were based on prothetic materials and the status of infection.Infectious meshes were removed completely in 2 cases and partially removed in 2 cases.Open dress change with meshes left in situ in 3 cases.2 cases of removed meshes were given immediate to saturate with closed drainage.2cases of partially removed mesh were drained by vacuum sealing drainage.Results Infection was cured in all cases without mortality.There was no hemorrhage and injury of bladder during the procedures.No retention of urine,pain and other complications during postoperation. Change of dressing was made from 7 days to 6 months(average 4 weeks).Selected antibiotic was used from 3 to 14 days(average 7.5 days).All patients were followed up from 2 to 42 months (average 18.5 months) without hernia recurrence and infection.Conclusions It was most important to prevent infections after tension-free hernioplasty.Management should be individualized according to different type of mesh used and the surgical procedure in hernia repair.