Gas- Water Alternate Membrane Bioreactor for Domestic Sewage Treatment

王宏杰,董文艺,李继
2011-01-01
Abstract:The treatment efficiency by the gasater alternate membrane bioreactor (AMBR) on domestic sewage was investigated through a pilot -scale study in order to get better application effect in the practical engineering. The results showed that : AMBR had good COD and NH4 + - N removal effect when the C/N ratio of raw domestic sewage was 4, and the COD and NH4 + - N concentration in effluent under 20 mg/L and 5 rag/ L. But it' s not good at TN removal because of its low C/N ratio, and the TN concentration in effluent was 22. 4 mg/L. When the C/N ratio of raw water increased to 6 according to adding glucose in raw domestic sew- age, the TN removal efficiency by AMBR was increased to 66% , and the effluent TN was only 13 rag/L, which met the First A - level requirement of China. Meanwhile, the COD and NH4 ~ - N removal effect by AMBR was unaffected by the change of the raw water' s C/N ration. The trans - membrane pressure was main- tained about- 20 kPa indicated that AMBR also had good membrane fouling alleviating effect.