Performance-enhanced cholesterol biosensor based on biocomposite system: Layered double hydroxides-chitosan
Shou-Nian Ding,Dan Shan,Tao Zhang,Yan-Zhi Dou
DOI: https://doi.org/10.1016/j.jelechem.2011.04.003
IF: 4.598
2011-01-01
Journal of Electroanalytical Chemistry
Abstract:Using layered double hydroxides (LDHs)-chitosan (Chit) composite as enzyme immobilization matrix, the developments of cholesterol biosensor were achieved by both electrooxidation and electroreduction of the enzymatic-generated hydrogen peroxide based on cholesterol oxidase (ChOx) and horseradish peroxidase (HRP). Amperometric detection of cholesterol was evaluated by holding the modified electrode at 0.55 V and 0 V (vs. SCE), for ChOx/LDHs-Chit/Pt and ChOx/HRP/LDHs-Chit/GCE, respectively. The linear dynamic ranges of anodic and cathodic detections of cholesterol were between 5 × 10 −7 to 8 × 10 −4 M and 4 × 10 −8 to 6 × 10 −4 M, respectively. The detection limits were determined to be of 1 × 10 −7 and 4 × 10 −8 M with anodic and cathodic processes, respectively. At potential of 0 V, ChOx/HRP/LDHs-Chit/GCE bienzymatic mediated system exhibited excellent selectivity and stability. Keywords Cholesterol oxidase Horseradish peroxidase Layered double hydroxides Chitosan Cholesterol Biosensor 1 Introduction Cholesterol and its fatty acids are important components of nerve and brain cells and are precursors of biological substances, such as bile acid and steroid hormones [1] . The balanced quantity of cholesterol in blood provides durability and integrity to the cell architecture. However, its elevated levels are associated with atherosclerosis, nephrosis, diabetes milletus, myxedema, jaundice and decreased levels may result in hyperthyroidism, anaemia and maladsorption [2,3] . Hence cholesterol determination is of great importance for clinical applications. Biosensors have recently gained much attention in the field of health care for the management of various important analytes in a biological system [4] . Among them, ChOx-based electrochemical biosensors have gained the tremendous progress for the determination of cholesterol [5–10] . Compared with other analytical techniques, such sensors possess simplicity of operation and the substrate selectivity of the enzymes. In addition, they are inexpensive since a small amount of immobilized enzyme (ChOx) can be used for a large number of analytical determinations. In most of conventional cholesterol sensors, ChOx catalyzes the conversion of cholesterol into 5-cholesten-3-one and hydrogen peroxide in the presence of oxygen, which can be detected amperometrically. However, several interfering compounds can contribute to the biosensor response due to the high potential usually required for H 2 O 2 detection. Therefore the development of high-performance cholesterol biosensor has been a focal subject in bioanalytical science and technology. In our previous works, layered double hydroxides (LDHs), have been demonstrated as attractive enzyme immobilization matrix [11–14] . LDHs display a layered structure built on a stacking of positive layers ([M 1− x II M x III (OH) 2 ] x + [15] . The electroneutrality of the system can be realized by the presence of changeable anions accompanied with water molecules situated in the interlamellar domains. Furthermore, the properties of LDHs can be efficiently improved by introduction biopolymer such as chitosan (Chit) [16,17] and alginate [18] . The biopolymer in the clay composite can not only overcome the brittleness of the pure clay film, but also increase the biocompatibility and the adhesive ability of the composite film to the electrode surface, resulting in the improved analytical performance of the biosensor. Moreover, the usage of glutaraldehyde, which can denature the enzyme, could be finally avoided [16–20] . This contribution describes the extended application of LDHs-Chit composite as enzyme immobilization matrix to construct highly performance-enhanced cholesterol biosensor. Two different enzyme systems have been checked involving monoenzyme ChOx on the one hand, and bienzyme ChOx/HRP coimmobilization, on the other hand. The analytical performance of the biosensors derived from both enzyme systems has been evaluated. 2 Experimental 2.1 Materials Cholesterol oxidase (ChOx) (EC1.1.3.6, 8.1 U mg −1 ) was obtained from Sigma. Horseradish peroxidase (HRP) (EC 1.11.1.7, type II, 140 U mg −1 ), cholesterol, brilliant cresyl blue (BCB), azure B and ferrocenemethanol (MeOHFc) were purchased from Amresco. Chitosan (CHT, MW ∼1 × 10 6 ; >90% deacetylation) Layered double hydroxides (LDHs) Zn 3 Al(OH) 8 Cl, denoted [Zn 3 –Al–Cl] was synthesized by coprecipitation method developed by De Roy [14,15] . All other reagents were of analytical grade and used as received without further purification. All aqueous solutions were prepared in deionized distilled water. Phosphate buffer (0.1 M) (pH 7.0) was used for all the experiments unless otherwise indicated. 2.2 Measurements and apparatus All electrochemical studies were performed with a conventional three-electrode system. A saturated calomel electrode (SCE) and a Pt foil electrode were used as reference electrode and counter electrode, respectively. The working electrode was a platinum disk electrode (diameter 2 mm) or glassy carbon electrode (diameter 3 mm), polished carefully with 0.05 μm alumina particles on silk followed by rinsing with the distilled water and dried in air before use. All measurements were carried out in a thermostated cell at 25 °C, containing phosphate buffer solution. 2.3 Preparation of enzyme electrodes A 2.0-wt% Chit solution was prepared by dissolving Chit flakes in 1.0-wt% acetic acid (HAc), and was then diluted into 0.2-wt% solution (about pH 4.0) by adding water. The LDHs [Zn 3 –Al–Cl] colloidal suspension (2 mg ml −1 ) was prepared by dispersing LDHs in deionized and decarbonated water stirring overnight. ChOx or HRP was also dissolved in deionized water with a concentration of 2 mg ml −1 . A defined amount of aqueous enzyme/LDHs-Chit mixture (for instance, containing 16 μg [Zn 3 –Al–Cl], 4 μg Chit and 20 μg enzyme) was spread on the surface of the platinum disk electrode or glassy carbon electrode. The coating was then dried at 4 °C in a refrigerator for overnight, leading to adherent LDHs/Chit film in which enzymes were entrapped. Before use, the enzyme electrode was rinsed under stirring for 20 min with buffer solution to remove the enzyme not firmly immobilized. 3 Results and discussion 3.1 ChOx/LDHs/Pt monoenzymatic system ChOx belongs to the family of oxidoreductases, specifically those acting on the CH–OH group of donor with oxygen as acceptor, which catalyzes the chemical reaction (as shown in Inset I of Fig. 1 ): cholesterol + O 2 cholest- 4 -en - 3 -one + H 2 O 2 As a consequence, the amperometric detection of cholesterol was assayed by potentiostating the ChOx/LDHs-Chit/Pt electrode at 0.55 V to oxidize the enzymatically generated hydrogen peroxide. ChOx/LDHs-Chit/Pt shows a rapid response to cholesterol (<6 s). Such a rapid response indicates a fast mass transfer of the substrate across the film and a fast electron exchange between ChOx and its substrates, highlighting the advantages of LDHs-Chit composite as host matrix for the construction of the biosensor. Inset II of Fig. 1 shows a typical calibration graph of ChOx/LDHs-Chit/Pt bioelectrode for the determination of cholesterol. It appears that the linear part of the calibration curve overlays a range of cholesterol concentration: from 0.5 to 800 μM with a correlation coefficient of 0.998 ( n = 10) and a detection limit of 0.1 μM cholesterol determined at a signal-to-noise ratio of 3. The cholesterol sensitivity is calculated to be 10.4 mA cm −2 M −1 . The effect of temperature on the ChOx/LDHs-Chit/Pt bioelectrode response to 0.1 mM cholesterol was evaluated between 10 and 55 °C. The current response gradually increases with increasing temperature and reaches a maximum at 50 °C (Curve a in Fig. 1 ). This value is greater than that observed for modified ChOx/Pt electrode in the absence of LDHs-Chit (Curve b in Fig. 1 ). Such a high optimal temperature of the running of the bioelectrode may be ascribed to the beneficial effect brought by LDHs-Chit as the enzyme host matrix. In the LDHs-Chit composite, the highly hydrophilic LDHs in this hybrid system can prevent the enzyme from thermal denaturation, simultaneously, the highly biocompatible Chit can further improve the biocompatibility of the host matrix, providing a friendly microenvironment for the entrapped enzyme. 3.2 ChOx/HRP/LDHs-Chit/GCE bienzymatic system 3.2.1 Selection of mediator To eliminate the interferences and improve the biosensor selectivity, an alternative approach was performed by enzyme-channeling assay [13,21] . Thus, the construction of bienzymatic ChOx/HRP amperometric biosensor was applied for cholesterol detection. Fig. 2 A shows the functioning principle of the composite biosensor based on the co-immobilization of ChOx and HRP within the LDHs-Chit hybrid matrix. In such configurations, H 2 O 2 produced by ChOx-cholesterol-dissolved oxygen system is detected through its HRP-mediated reduction, which might permit the detection of cholesterol at low potential and can avoid the interference of the coexisting electroactive substances. Three mediators, namely, Brilliant cresyl blue (BCB), azure B and ferrocenemethanol (MeOHFc), were investigated for this ChOx-HRP bienzymatic system for cholesterol. BCB and azure B belong to phenothiazine and methylated thiazine dyes, respectively. They are charged positively. However, MeOHFc is charged neutrally. As shown in curve a of Fig. 2 B, C and D, in the absence of the cholesterol, the anodic and cathodic voltammetric peaks, are attributed to the redox signal of the corresponding mediator. But in the presence of 0.1 mM cholesterol, the cyclic voltammogram displays an enhancement of the cathodic peak current and a concomitant decrease of the anodic peak current (curve b of Fig. 2 B–D). This suggests that cholesterol could be oxidized catalytically at the ChOx/HRP/LDHs-Chit /GCE-mediated system. Compared among the above-mentioned mediators, MeOHFc as mediator can realize the detection of cholesterol at 0 V vs. SCE. Thus, MeOHFc was selected in this ChOx/HRP/LDHs-Chit/GCE-mediated system. 3.3 MeOHFc mediated bienzymatic system for cholesterol detection Fig. 3 depicts typical cyclic voltammograms of bienzyme sensor in 0.1 M PBS (pH = 7 containing 0.1 mM MeOHFc at different scan rate. The plots of the peak current ( i p ) against ν 1/2 according to the Randles–Sevick equation demonstrate the strong linear relationships ( R 2 = 1, for both i pa ∼ ν 1/2 and i pc ∼ ν 1/2 , respectively) for this bienzyme-MeOHFc system (inset of Fig. 3 ). The linear behavior of the peak current with the square root of scan rate indicates that the redox behavior of the electrode is diffusion controlled. Thus, the oxidized and reduced forms of MeOHFc in the solution are not adsorbed on ChOx/HRP/LDHs-Chit-modified GCE. Since ChOx catalyzes the aerobic oxidation of cholesterol with concomitant production of H 2 O 2 , the amperometric response of the bienzymatic ChOx/HRP/LDHs-Chit/GCE to cholesterol was also investigated in this present work. The dependence of the MeOHFc-mediated bienzyme electrode response on the applied potential was evaluated over the potential range from −0.15 to 0.1 V for cholesterol in 0.1 M PBS (pH 7.0) ( Fig. 4 ). The optimal applied potential can be observed at 0 V vs. SCE. Consequently, an operational potential value of 0 V was chosen for subsequent amperometric measurements for cholesterol. Fig. 5 displays the typical amperometric response of the biosensor based on bienzyme-MeOHFc sensing system for successive injection of cholesterol to stirring 10 ml 0.1 M PBS at pH 7.0. The response current of the biosensor is linear in the range from 4 × 10 −8 to 6 × 10 −4 M with a low detection limit of 4 × 10 −8 based on signal/noise = 3 and a correlation coefficient of 0.997 ( n = 30). The analytical performances of the proposed biosensor were compared with those cholesterol sensors, as summarized in Table 1 . It appears that the relative low detection limit was obtained with the ChOx/HRP/LDHs-Chit/GCE-MeOHFc system. This improved detection limit can be also ascribed to the low applied potential which provided low background current. 3.4 Stability for the MeOHFc-mediated bienzyme electrode to cholesterol The reproducibility of the analytical responses obtained from different electrodes constructed by the same procedure was analyzed. Seven different electrodes were tested independently for these amperometric responses to 0.1 mM cholesterol. The results revealed that the relative standard deviation (RSD) value for all seven electrodes was 5.6%. Both operational and long-term storage stability are very important form the pratical application point of view [19] , so these two parameters were also examined. The operational stability of the ChOx/HRP/LDHs-Chit/GCE-MeOHFc mediated system was examined. A reproducible current response with a RSD of 3.0% was observed in 60 successive assay of 0.1 mM cholesterol ( Fig. 6 A). The long-term stability of this proposed mediated bienzymatic system was also investigated by recording periodically. Its biosensor retained 92.8% and 62.5% of its cholesterol sensitivity after 14 and 40 days, respectively ( Fig. 6 B). This good stability reflects the biocompatibility of the LDHs-Chit composite and its efficient retention properties towards enzyme molecules. 3.5 Interference study The interferences of electroactive species to the cholesterol response were examined in the presence of their physiological normal levels with cholesterol concentration at 0.1 mM [22,23] . Interference was estimated as the percentage increase in the biosensor signal recorded in the presence of interferents compared with the stead-state biosensor response to 0.1 mM cholesterol alone. The influences of ascorbic acid (0.1 mM), p -acetamidophenol (0.05 mM), l -cysteine (0.02 mM), glucose (5.6 mM), and reduced glutathione (2 mM) were estimated in this work with two cholesterol sensors, namely, the monoenzymatic electrode (ChOx/LDHs-Chit/Pt applied at 0.55 V vs. SCE) and mediated bienzymatic system (ChOx/HRP/LDHs-Chit/Pt-MeOHFc). The results are illustrated in Fig. 7 . The influence of ascorbic acid, p -acetamodophenol, l -cysteine, glucose and reduced glutathione were effectively reduced with the mediated bienzymatic system (ChOx/HRP/LDHs-Chit/GCE-MeOHFc). This is ascribed to the efficiency of the electrocatalytic process in the whole structure of LDHs-Chit matrix and also to the value of the low operating potential of 0 V vs. SCE. 4 Conclusion The development of amperometric biosensor for monitoring cholesterol was described in this paper. Due to the satisfactory biocompatibility, attractive interfacial properties, LDHs-Chit was further confirmed as a host enzyme immobilization matrix for constructing both monoenzymatic and multienzymatic biosensors. Cholesterol sensor based on LDHs-Chit exhibited the highly developed analytical performance to cholesterol such as rapid response, high sensitivity and good stability. In addition, the proposed cholesterol biosensor by coupling of HRP with ChOx permitted the selective detection of cholesterol at 0 V vs. SCE and could avoid the interference of coexisting substances. Acknowledgements The authors are grateful to the financial supports of National Natural Science Foundation of China (Grant Nos. 20905011, 21010102071), the Natural Science Foundation of Jiangsu (No. BK2010396), University science research project of Jiangsu Province (09KJB150015), and the Open Research Fund of State Key Laboratory of Bioelectronics, Southeast University. This work was also supported by the Southeast University Creative Foundation (3207040501). References [1] S. Aravamudhan A. Kumar S. Mohapatra S. Bhansali Biosens. Bioelectron. 22 2007 2289 2294 [2] M. Nauck W. März H. Wieland Clin. Chem. 46 2000 436 437 [3] V. Malik C.S. Pundir Biotechnol. Appl. Biochem. 35 2002 191 197 [4] S.K. Arya M. Datta B.D. Malhotra Biosens. Bioelectron. 23 2008 1083 1100 [5] A.I. Gopalan K.P. Lee D. Ragupathy Biosens. Bioelectron. 24 2009 2211 2217 [6] W.C. Shih M.C. Yang M.S. Lin Biosens. Bioelectron. 24 2009 1679 1684 [7] C. Dhand S.K. Arya S.P. Singh B.P. Singh M. Datta B.D. Malhotra Carbon 46 2008 1727 1735 [8] A. Kaushik P.R. Solanki K. Kaneto C.G. Kim S. Ahmad B.D. Malhotra Electroanalysis 22 2010 1045 1055 [9] Z. Matharu G. Sumana S.L. Arya S.P. Singh V. Gupta B.D. Malhotra Langmuir 23 2007 13188 13192 [10] Z. Matharu S.K. Arya S.P. Singh V. Gupta B.D. Malhotra Anal. Chim. Acta 634 2009 243 249 [11] D. Shan S. Cosnier C. Mousty Anal. Chem. 75 2003 3872 3879 [12] D. Shan C. Mousty S. Cosnier Anal. Chem. 76 2004 178 183 [13] D. Shan S. Cosnier C. Mousty Anal. Lett. 36 2003 909 922 [14] D. Shan W.J. Yao H.G. Xue Electroanalysis 18 2006 1485 1491 [15] A. De Roy, C. Forano, K. El Malki, J.P. Besse, Expanded clays and other microporous solids, in: M.L. Occelli, H.E. Robson (Ed.), Expanded clays and other microporous solid, Van Nostrand Reinhold, New York, 1992, pp. 108–169. [16] E. Han D. Shan H.G. Xue S. Cosnier Biomacromolecules 8 2007 971 975 [17] Q.F. Shi E. Han D. Shan W.J. Yao H.G. Xue Bioprocess Biosyst. Eng. 31 2008 519 526 [18] S.N. Ding D. Shan H.G. Xue D.B. Zhu S. Cosnier Y.M. Sun Anal. Sci. 25 2009 1421 1425 [19] Q. Fan D. Shan H.G. Xue Y.Y. He S. Cosnier Biosens. Bioelectron. 22 2007 816 821 [20] Q.F. Shi Q.B. Li D. Shan Q. Fan H.G. Xue Mater. Sci. Eng. C 28 2008 1372 1375 [21] S. Cosnier C. Mousty X.Q. Cui X.R. Yang S.J. Dong Anal. Chem. 78 2006 4985 4989 [22] D. Shan M.J. Zhu H.G. Xue S. Cosnier Biosens. Bioelectron. 22 2007 1612 1617 [23] D. Shan Y.Y. He S.X. Wang H.G. Xue H. Zheng Anal. Biochem. 356 2006 215 221 [24] C.Z. Zhao L. Wan L. Jiang Q. Wang K. Jiao Anal. Biochem. 383 2008 25 30 [25] K.M. Manesh P. Santhosh A.L. Gopalan K.P. Lee Electroanalysis 22 2010 2467 2474 [26] H. Ohnuki R. Honjo H. Endo T. Imakubo M. Izumi Thin Solid Films 518 2009 596 599
What problem does this paper attempt to address?
-
Amperometric Micro-Biosensor Based on Cholesterol Determination
管文军,胡贵权,李光,廖静敏,陈裕泉
DOI: https://doi.org/10.3969/j.issn.1004-1699.2003.03.015
2003-01-01
Abstract:Printed graphite electrode based micro biosensor containing cholesterol oxidase, cholesterol esterase and peroxidase was developed. It was used for whole blood total cholesterol determination. Enzymes in reactive system were immobilized on the surface of graphite electrode through trehalose embedding. The biosensor's linear range is 100~400 mg/dl, sample volume is 2 microlitre and detecting time is 180 s. The problem of inactivation of bioactive substances has been solved and stable storage time of the biosensor is more than six months.
-
Layer-by-layer Chitosan-Decorated Pristine Graphene on Screen-Printed Electrodes by One-Step Electrodeposition for Non-Enzymatic Hydrogen Peroxide Sensor
Qin Zhu,Bo Liang,Yu Cai,Qingpeng Cao,Tingting Tu,Bobo Huang,Lu Fang,Xuesong Ye
DOI: https://doi.org/10.1016/j.talanta.2018.07.038
IF: 6.1
2018-01-01
Talanta
Abstract:Layer-by-layer chitosan-decorated pristine graphene on screen-printed electrodes was achieved by one-step electrodeposition method and an enzyme-free hydrogen peroxide electrochemical biosensor was fabricated for its application. Negatively charged pristine graphene absorbed with positively charged chitosan by electrostatic interactions was electrodeposited on the electrodes. The successful immobilization of pristine graphene was confirmed by scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS) and electrochemical characterizations. The graphene-chitosan volume ratio and cyclic voltammetry scan cycles during the electrodeposition process were optimized. The resulting hydrogen peroxide biosensors showed a 178 times improved sensitivity and exhibited two wide linear detection ranges from 20 μM to 20 mM and from 20 mM to 60 mM. The biosensors also showed a good reproducibility, stability, selectivity and could be used in real samples detection. The superior electrochemical performance of graphene-chitosan was attributed to the preservation of excellent properties of pristine graphene, and the formation of layer-by-layer structure with high surface area. The proposed strategy of direct immobilization of pristine graphene can be extended for the immobilization of other nanomaterials and biomolecules.
-
Direct Electrochemistry of Cholesterol Oxidase Immobilized on PEDOT Functionalized Screen-Printed Electrodes
Rongxiang Shi,Junhao Chen,Xiaofang Wan,Junfei Tian
DOI: https://doi.org/10.1149/1945-7111/acbac2
IF: 3.9
2023-02-11
Journal of The Electrochemical Society
Abstract:To address the problems of the high cost and cumbersome preparation process in the current construction of cholesterol sensors, a third-generation electrochemical cholesterol sensor with a facile preparation method, low cost, enhanced sensitivity, and wide linear range was investigated. The cholesterol sensor was constructed by immobilizing cholesterol oxidase (ChOx) on a poly-3,4-ethylenedioxythiophene (PEDOT) modified screen-printed electrode. This study shows a very simple fabrication process. The electrodes were constructed only in three steps, including in situ electropolymerization of PEDOT, enzyme introduction and encapsulation of the Nafion membrane. The successful modification of PEDOT was demonstrated by energy dispersive X-ray spectroscopy and Fourier-transform infrared spectroscopy. The morphological characterization and electrochemical analysis showed that the presence of PEDOT not only provided more anchoring sites for immobilizing enzymes, but also its high electrocatalytic activity enabled direct electron transfer between the ChOx and the electrode surface. The linear range for the actual detection of cholesterol was 50-800 μM, the sensitivity was 1.34 μA mM -1 , and the electrical signal was not affected by interfering substances such as uric acid, glucose, dopamine, and ascorbic acid. Therefore, the cholesterol biosensor constructed in this paper was expected to achieve large-scale applications.
electrochemistry,materials science, coatings & films
-
Potassium-doped carbon nanotubes toward the direct electrochemistry of cholesterol oxidase and its application in highly sensitive cholesterol biosensor
XiaoRong Li,Jingjuan Xu,Hongyuan Chen
DOI: https://doi.org/10.1016/j.electacta.2011.08.020
IF: 6.6
2011-01-01
Electrochimica Acta
Abstract:We demonstrate herein a newly developed serum total cholesterol biosensor by using the direct electron transfer of cholesterol oxidase (ChOx), which is based on the immobilization of cholesterol oxidase and cholesterol esterase (ChEt) on potassium-doped multi-walled carbon nanotubes (KMWNTs) modified electrodes. The KMWNTs accelerate the electron transfer from electrode surface to the immobilized ChOx, achieving the direct electrochemistry of ChOx and maintaining its bioactivity. As a new platform in cholesterol analysis, the resulting electrode (ChOx/KMWNTs/GCE) exhibits a sensitive response to free cholesterol, with a linear range of 0.050–16.0μmolL−1 and a detection limit of 5.0nmolL−1 (S/N=3). Coimmobilization of ChEt and ChOx (ChEt/ChOx/KMWNTs/GCE) allows the determination of both free cholesterol and esterified cholesterol. The resulting biosensor shows the same linear range of 0.050–16.0μmolL−1 for free cholesterol and cholesteryl oleate, with the detection limit of 10.0 and 12.0nmolL−1 (S/N=3), respectively. The concentrations of total (free and esterified) cholesterol in human serum samples, determined by using the techniques developed in the present study, are in good agreement with those determined by the well-established techniques using the spectrophotometry.
-
Hydrogen peroxide biosensor based on chitosan/2D layered double hydroxide composite for the determination of H2O2
Jian Yuan,Sheng Xu,Hong-Yan Zeng,Xi Cao,A Dan Pan,Gao-Fei Xiao,Peng-Xuan Ding
DOI: https://doi.org/10.1016/j.bioelechem.2018.04.009
IF: 5.76
Bioelectrochemistry
Abstract:The composites (LDH-CMC) composed of carboxymethyl chitosan (CMC) and 2D ZnAl layered double hydroxide (LDH) were successfully prepared using the one-step urea method; these composites were characterized by XRD, FT-IR, UV-vis DRS, SEM, BJH/BET, TG-DTG and pHzpc analyses, cyclic voltammetry, and electrochemical impedance spectroscopy. The use of CMC could impact the textural and surface chemical properties of the LDH-CMC composites, where the composites still maintained the 2D layered structure. Incorporating a moderate amount of CMC could increase both the surface area and the permanent charge density of the composites, leading to improved electrochemical performances. The LDH-CMC composite was used as a support matrix for the immobilization of horseradish peroxidase (HRP) on the glass carbon (GC) electrode to construct a biosensor that provides a biocompatible microenvironment for HRP and a pathway for H2O2 diffusion via the high surface area. The HRP biosensor displayed a satisfactory sensitivity and fast response (<3 s) toward H2O2 over a wide linear range of 0.02-6.0 mmol·L-1 with a low detection limit of 12.4 μmol·L-1, good anti-interference ability and long-term storage stability. The proposed HRP biosensor was found to be a sensitive, rapid, and disposable sensor with low cost, easy preparation and high selectivity; thus, the proposed biosensor can be used for the real-time detection of trace H2O2 in the biological, clinical and environmental fields.
-
Bio-inspired enzyme-immobilized nanoreactors with cascade catalytic reaction for accurate detection of cholesterol
Jing Xiong,Lingling Shang,Decai Zhao,Dan Wang
DOI: https://doi.org/10.1007/s40843-024-2936-3
2024-06-20
Science China Materials
Abstract:Although enzyme-based biochemical detection offers high accuracy and speed, their applications are limited by the instability of biological enzymes. Developing an enzyme-encapsulated system with high activity, strong stability, and high reaction efficiency is a crucial strategy for cholesterol detection. Herein, we developed a bionic artificial cell with hollow multishelled structures (HoMS) covered by phospholipid membranes. The compartmentalized structure and selective permeability of this artificial cell enable stable enzyme encapsulation and efficient signal transmission, achieving rapid and accurate cholesterol detection through signal cascade amplification. Cholesterol oxidase-loaded HoMS@DPPC was used to initiate cholesterol oxidation reaction, and the resulting intermediate product H 2 O 2 was regarded as signal molecules to enter horseradish peroxidase-loaded HoMS@DPPC, promoting Amplex Red to produce resorufin. The amplification of cholesterol signal mediated by cascade catalysis makes the present system applicable to the detection of cholesterol, and the method shows high selectivity and accuracy, with a detection range of 0.05–0.3 mM and a detection limit of 4.9 μM. It can be used for the detection of cholesterol in animal serum with a recovery of 90.8% to 104.9%, highly consistent with the results of commercial detection methods. Furthermore, the system can be integrated with smart devices to build an intelligent colorimetric platform, enabling the integration of image analysis and cholesterol concentration detection, opening up a new path for accurate and rapid biochemical detection.
materials science, multidisciplinary
-
Cholesterol oxidase-immobilized MXene/sodium alginate/silica@n-docosane hierarchical microcapsules for ultrasensitive electrochemical biosensing detection of cholesterol
Meng Zhang,Huan Liu,Xiaodong Wang
DOI: https://doi.org/10.1039/d2tb02367a
IF: 7.571
2022-12-20
Journal of Materials Chemistry B
Abstract:Electrochemical biosensors usually suffer from the deterioration of detection sensitivity and determination accuracy in high-temperature environment due to protein denaturation and inactivation of their biological recognition elements such as enzymes. Focusing on an effective solution to this crucial issue, we have developed the cholesterol oxidase-immobilized MXene/sodium alginate/silica@ n -docosane hierarchical microcapsules as a thermoregulatory electrode material for electrochemical biosensors to meet the requirement of ultrasensitive detection of cholesterol at high temperature. The microcapsules were first fabricated by microencapsulating n -docosane as a phase change material (PCM) in a silica shell, followed by depositing a biocompatible sodium alginate layer, wrapping with electroactive MXene nanosheets and then immobilizing cholesterol oxidase as a biological recognition element for electrochemical biosensing. The fabricated composites not only exhibited a layer-by-layer hierarchical microstructure with the desired chemical and biological components, but also obtained a high latent-heat capacity of over 133 J/g for thermal management through reversible phase transitions of its PCM core. A bare glassy carbon electrode was modified with the developed composites to serve for the cholesterol biosensor. This enables the modified electrode to obtain an in-situ thermoregulatory ability to regulate the microenvironmental temperature surrounding the electrode, effectively preventing the protein denaturation of cholesterol oxidase and minimizing heat impact to biosensing performance. Compared to conventional cholesterol biosensors without a PCM, the developed biosensor achieved a higher sensitivity of 4.63 μA·μM –1 ·cm –2 and a lower limit of detection of 0.081 μM at high temperature, providing high-accurate and reliable cholesterol detection for real biological samples over a wide temperature range.
materials science, biomaterials
-
Cost‐Effective Cholesterol Monitoring by Enzyme‐Based Electrochemical Assay
Ece Eksin,Huseyin Senturk,Arzum Erdem
DOI: https://doi.org/10.1002/slct.202304593
2024-01-26
ChemistrySelect
Abstract:We report a practical, disposable, enzyme‐based electrochemical assay for measuring salivary cholesterol levels. Electrochemical impedance spectroscopy is used for the sensing of cholesterol after its interaction with cholesterol oxidase onto PGE surface. The proposed biosensor ensures a rapid response time (20‐minute) and low detection limit (95 μM). This approach promises a practical, point‐of‐care diagnostic solution for cholesterol monitoring. Herein we present a practical, disposable, enzyme‐based electrochemical biosensor to revolutionize a rapid and precise measurement of cholesterol level in saliva. To create a biosensor that can measure cholesterol levels, cholesterol oxidase (ChOx) was immobilized on disposable pencil graphite electrode (PGE) via EDC/NHS chemistry. This ChOx‐PGE biosensor has been characterized using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS). Various critical experimental parameters, including nafion concentration, enzyme concentration, enzyme‐cholesterol interaction time, were optimized ensuring consistency and precision in our results and maintained constant throughout the experiments. Under optimum conditions, the detection limit was found to be 62 μM and the sensitivity of the sensor was calculated as 1112.8 Ohm mM−1 cm−2. The potential interferences such as glucose, ascorbic acid, uric acid, cysteine was selected to test the selectivity and no significant response was observed. Finally, the proposed biosensor was effectively employed to measure cholesterol level in saliva. This biosensor boasts a rapid response time of just 20 minutes and achieves a remarkable detection limit of 95 μM for salivary cholesterol, surpassing existing techniques. Our assay not only offers an innovative solution for cholesterol monitoring but also opens new horizons in point‐of‐care diagnostics with its disposable and practical design.
chemistry, multidisciplinary
-
Cholesterol Oxidase Sensor Based on Cobalt Protoporphyrin Modified Electrode
Dong Shao
1993-01-01
Abstract:A new amperometric sensor for free cholesterol has been fabricated based on a high electrocatalytic activity of cobalt protoporphyrin to the oxidation of H2O2. A layer of cobalt pro-toporphyrin was absorbed on the glassy carbon electrode, the enzyme film consisting of bovine serum albumin and cholesterol oxidase was put on it, then a layer of poly(ο-phenylenediamine) film was electropolymerized out of the enzyme film to avoid interference and fouling. The linear range of concentration was 0. 1 mmol/L -2 mmol/L. The response time was less than 30 s. The electrode was used for 150 times assays without loss of any enzymatic activity.
-
MXene-based enzymatic sensor for highly sensitive and selective detection of cholesterol
Tianzi Xia,Guangyan Liu,Junjie Wang,Shili Hou,Shifeng Hou
DOI: https://doi.org/10.1016/j.bios.2021.113243
IF: 12.545
2021-07-01
Biosensors and Bioelectronics
Abstract:<p>In this work, the synthesized MXene (Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub>) exhibited large specific area, biocompatibility, excellent electronic conductivity, and good dispersion in aqueous phase. The Chit/ChOx/Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub> nanocomposite was prepared through the continuous self-assembled process. Its structure is characterized by scanning electron microscopy (SEM), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and differential pulse voltammetry (DPV). Moreover, the biosensor for cholesterol detection was fabricated via a one-step dip-coating method. Chit andTi<sub>3</sub>C<sub>2</sub>T<sub>x</sub> act as a support matrix to immobilize ChOx enzyme, and also play a role in increasing the electrical conductivity. Meanwhile, the addition of redox mediator (Fe(CN)<sub>6</sub><sup>3</sup><sup>-</sup><sup>/4-</sup>) facilitates the electron transport from the analyte to the modified electrode in the oxidation of cholesterol. The DPV response exhibited an increase in current with increasing cholesterol concentration. Under the optimum conditions, the DPV response of the biosensor indicated a good linear relationship with the concentration of cholesterol ranging from 0.3 to 4.5 nM with a low detection limit of 0.11 nM, and a high sensitivity of 132.66 μA nM<sup>−1</sup> cm<sup>−2</sup>. In addition, with favorable selectivity and stability, the biosensor has been used to detect cholesterol in real samples and the results demonstrate that the biosensor has excellent practicability.</p>
biotechnology & applied microbiology,biophysics,chemistry, analytical,electrochemistry,nanoscience & nanotechnology
-
Solid-Phase Electrochemiluminescence Enzyme Electrodes Based on Nanocage Arrays for Highly Sensitive Detection of Cholesterol
Xinying Ma,Zhe Zhang,Yanyan Zheng,Jiyang Liu
DOI: https://doi.org/10.3390/bios14080403
2024-08-22
Biosensors
Abstract:The convenient and sensitive detection of metabolites is of great significance for understanding human health status and drug development. Solid-phase electrochemiluminescence (ECL) enzyme electrodes show great potential in metabolite detection based on the enzyme-catalyzed reaction product hydrogen peroxide (H2O2). Herein, a solid-phase ECL enzyme sensor was fabricated based on a confined emitter and an immobilized enzyme using electrostatic nanocage array, constructing a platform for the sensitive detection of cholesterol. The electrostatic cage nanochannel consists of a bipolar and bilayer vertically aligned mesoporous silica film (bp-VMSF). The upper layer of bp-VMSF is an amino-modified, positively charged VMSF (p-VMSF), and the lower layer is a negatively charged VMSF (n-VMSF). The most commonly used ECL probe tris(bipyridine)ruthenium(II) (Ru(bpy)32+) is fixed in n-VMSF by electrostatic adsorption from n-VMSF and electrostatic repulsion from the upper p-VMSF, generating significantly enhanced and stable ECL signals. The successful preparation of the electrostatic cage was characterized by scanning electron microscopy (SEM) and electrochemical methods. After amino groups on the outer surface of bp-VMSF were derivatized with aldehyde, cholesterol oxidase (ChOx) molecules were covalently immobilized. The successful construction of the enzyme electrode was characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). When the corresponding enzyme substrate, cholesterol, was present in the solution, the ECL signal of Ru(bpy)32+ was quenched by the enzyme-catalyzed reaction product H2O2, enabling the high-sensitivity detection of cholesterol. The linear range for detecting cholesterol was from 0.05 mM to 5.0 mM, with a limit of detection (LOD) of 1.5 μM.
chemistry, analytical,nanoscience & nanotechnology,instruments & instrumentation
-
A sensitive cholesterol electrochemical biosensor based on biomimetic cerasome and graphene quantum dots
Shuyao Wu,Meijiao Jiang,Hui Mao,Nan Zhao,Dongqing He,Qinan Chen,Daliang Liu,Wei Zhang,Xi-Ming Song
DOI: https://doi.org/10.1007/s00216-022-03986-9
2022-02-26
Analytical and Bioanalytical Chemistry
Abstract:AbstractA simple and sensitive electrochemical cholesterol biosensor was fabricated based on ceramic-coated liposome (cerasome) and graphene quantum dots (GQDs) with good conductivity. The cerasome consists of a lipid-bilayer membrane and a ceramic surface as a soft biomimetic interface, and the mild layer-by-layer self-assembled method as the immobilization strategy on the surface of the modified electrode was used, which can provide good biocompatibility to maintain the biological activity of cholesterol oxidase (ChOx). The GQDs promoted electron transport between the enzyme and the electrode more effectively. The structure of the cerasome-forming lipid was characterized by Fourier transform infrared (FT-IR). The morphology and characteristics of the cerasome and GQDs were characterized by transmission electron microscopy (TEM), zeta potential, photoluminescence spectra (PL), etc. The proposed biosensors revealed excellent catalytic performance to cholesterol with a linear concentration range of 16.0 × 10−6–6.186 × 10−3 mol/L, with a low detection limit (LOD) of 5.0 × 10−6 mol/L. The Michaelis–Menten constant (Km) of ChOx was 5.46 mmol/L, indicating that the immobilized ChOx on the PEI/GQDs/PEI/cerasome–modified electrode has a good affinity to cholesterol. Moreover, the as-fabricated electrochemical biosensor exhibited good stability, anti-interference ability, and practical application for cholesterol detection.Graphical abstract
-
Cholesterol biosensor based on rf sputtered zinc oxide nanoporous thin film
S. P. Singh,Sunil K. Arya,Pratibha Pandey,B. D. Malhotra,Shibu Saha,K. Sreenivas,Vinay Gupta
DOI: https://doi.org/10.1063/1.2768302
IF: 4
2007-08-06
Applied Physics Letters
Abstract:Cholesterol oxidase (ChOx) has been immobilized onto zinc oxide (ZnO) nanoporous thin films grown on gold surface. A preferred c-axis oriented ZnO thin film with porous surface morphology has been fabricated by rf sputtering under high pressure. Optical studies and cyclic voltammetric measurements show that the ChOx∕ZnO∕Au bioelectrode is sensitive to the detection of cholesterol in 25–400mg∕dl range. A relatively low value of enzyme’s kinetic parameter (Michaelis-Menten constant) ∼2.1mM indicates enhanced enzyme affinity of ChOx to cholesterol. The observed results show promising application of nanoporous ZnO thin film for biosensing application without any functionalization.
physics, applied
-
A Sensitive Enzymatic Electrochemical Biosensor for Cholesterol Based on Cobalt Ferrite@Molybdenum Disulfide/Gold Nanoparticles
Nagarajan Ayyandurai,Sethuraman Venkatesan,Sasikumar Raman
DOI: https://doi.org/10.1021/acsabm.4c00412
2024-06-17
Abstract:Cholesterol is essential in biological systems, and the level of cholesterol in the body of a person acts as a diagnostic marker for a variety of diseases. So, in this work, we fabricated an enzymatic electrochemical biosensor for cholesterol using cobalt ferrite@molybdenum disulfide/gold nanoparticles (CoFe2O4@MoS2/Au). The synthesized composite was used for the determination of cholesterol by voltametric methods. The electroactive material CoFe2O4@MoS2/Au was successfully verified from the physiochemical studies such as XRD, Raman, FT-IR, and XPS spectroscopy along with morphological FESEM and HRTEM characterization. CoFe2O4@MoS2/Au showed outstanding dispersion in the aqueous phase, a large effective area, good biological compatibility, and superior electronic conductivity. The microflower-like CoFe2O4@MoS2/Au was confirmed by scanning electron microscopy. The image of transmission electron microscopy showed decoration of gold nanoparticles on CoFe2O4@MoS2 surfaces. Furthermore, a one-step dip-coating technique was used to build the biosensor used for cholesterol detection. In addition to acting as an enabling matrix to immobilize cholesterol oxidase (ChOx), CoFe2O4@MoS2/Au contributes to an increase in electrical conductivity. The differential pulse voltammetry method was used for the quantitative measurement of cholesterol. The calibration curve for cholesterol was linear in the concentration range of 5 to 100 μM, with a low limit of detection of 0.09 μM and sensitivity of 0.194 μA μM-1 cm-2. Furthermore, the biosensor demonstrates good practicability, as it was also employed for identifying cholesterol in real samples with acceptable selectivity and stability.
-
A layer-by-layer assembled and carbon nanotubes/gold nanoparticles-based bienzyme biosensor for cholesterol detection
Xiaojun Cai,Xia Gao,Lisha Wang,Qi Wu,Xianfu Lin
DOI: https://doi.org/10.1016/j.snb.2013.02.050
2013-01-01
Abstract:A bienzyme biosensor for the detection of cholesterol, based on functionalized carbon nanotubes (CNTs) was fabricated through layer-by-layer (LBL) assembly technique. Being wrapped with cationic poly(allylamine hydrochloride) (PAH), the nanocomposite, multiwalled carbon nanotubes (MCNTs) mixed with gold nanoparticles (GNPs) was water soluble and positively charged. Based on reliably electrostatic interaction, bienzyme biosensor was then fabricated by LBL assembly of the positively charged nanocomposite and the negatively charged enzymes, horseradish peroxidase (HRP) and cholesterol oxidase (ChOx). The fabricated process and the electrochemical behaviors of the biosensor were investigated by scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). Under the optimal conditions, the bienzyme biosensor obtained the linear range from 0.18 to 11mM, with a detection limit of 0.02mM. The proposed biosensor exhibited good sensitivity, stability, and controllability for the detection of cholesterol.
-
Highly sensitive electrochemical detection of cholesterol based on Au–Pt NPs/PAMAM–ZIF-67 nanomaterials
Liangtian Zhang,Jianmeng Zhu,Wenzhong Hong,Gang Li
DOI: https://doi.org/10.1007/s44211-023-00427-0
IF: 1.967
2023-09-26
Analytical Sciences
Abstract:A cholesterol biosensor was constructed by bimetallic (Au and Pt) and poly(amidoamine)-zeolite imidazole framework (PAMAM–ZIF-67). First, PAMAM–ZIF-67 nanomaterial was immobilized onto the electrode, and then Au and Pt were modified on the electrode by the electro-deposition method. Subsequently, cholesterol oxidase (ChOx) and cholesterol esterase (ChEt) were fixed on the electrode. The stepwise modification procedures were recorded by impedance spectroscopy and voltammetry. The current response presented a linear relation to the logarithm of cholesterol content when content ranged between 0.00015 and 10.24 mM, and the minimum detection concentration reached 3 nM. The electrode was also used for the cholesterol assay in serum, which hinted at its potentially valuable in clinical diagnostics.
chemistry, analytical
-
Highly Sensitive Amperometric Cholesterol Biosensor Based on Pt-Incorporated Fullerene-like ZnO Nanospheres
Ahmad Mashkoor,Pan Caofeng,Gan Lin,Nawaz Zeeshan,Zhu Jing
DOI: https://doi.org/10.1021/jp9089497
2010-01-01
Abstract:A highly sensitive amperometric biosensor based on Pt-incorporated fullerene-like ZnO hybrid nanospheres has been investigated. Pt-ZnO nanospheres (PtZONS) with diameters in the range 50-200 nm have been successfully synthesized by electrodeposition on a glassy carbon electrode (GCE). The Pt nanoparticles in ZnO nanospheres have been identified with high-resolution transmission electron microscopy (HRTEM) and energy dispersive X-ray spectroscopy (EDS). The doped Pt nanoparticles demonstrate the abilities to electrocatalyze the oxidation of hydrogen peroxide and substantially raise the response current. The sensitivity of the PtZONS/GCE to hydrogen peroxide is 147.8 mu A mu M-1 cm(-2), which is much higher than that of a conventional electrode. The PtZONS/GCE was functionalized with cholesterol oxidase (ChOx) by physical adsorption. The enzyme electrode exhibits a very high and reproducible sensitivity of 1886.4 mA M-1 cm(-2) to cholesterol with a response time less than 5 s and a linear range from 0.5 to 15 mu M. Furthermore, it has been revealed that the biosensor exhibits a good anti-interference ability and favorable stability over relatively long-term storage (more than 5 weeks). All these results strongly suggest that the PtZONS not only enhance the sensitivity to cholesterol but also help to eliminate the interference at low applied potential.
-
A MgO Nanoparticles Composite Matrix‐Based Electrochemical Biosensor for Hydrogen Peroxide with High Sensitivity
Limin Lu,Li Zhang,Xiaobing Zhang,Zaisheng Wu,Shuangyan Huan,Guoli Shen,Ruqin Yu
DOI: https://doi.org/10.1002/elan.200900429
IF: 3.077
2010-01-01
Electroanalysis
Abstract:A novel horseradish peroxidase (HRP) electrochemical biosensor based on a MgO nanoparticles (nano-MgO)-chitosan (chit) composite matrix was developed. The morphology of nano-MgO-chit nanocomposite was examined by scanning electron microscopy (SEM). The interaction between nano-MgO-chit nanocomposite matrix and enzyme was characterized with UV-vis spectra. This proposed composite material combined the advantages of inorganic nanoparticles and organic polymer chit. The HRP immobilized in the nanocomposite matrix displayed excellent electrocatalytic activity to the reduction of H2O2 in the presence of hydroquinone as a mediator. The effects of the experimental variables such as solution pH and the working potential were investigated using steady-state amperometry. The present biosensor (HRP-modified electrode) had a fast response towards H2O2 (less than 10 s), and excellent linear relationships were obtained in the concentration range of 0.1 - 1300 mu M, with a detection limit of 0.05 mu M (S/N = 3). Moreover, the stability and reproducibility of this biosensor were evaluated with satisfactory results.
-
Cholesterol oxidase immobilized inulin based nanocomposite as the sensing material for cholesterol in biological and food samples
Kalaivani G Jayanthi,Suja S K
DOI: https://doi.org/10.1016/j.enzmictec.2020.109631
Abstract:In the present study, inulin based nanocomposite viz., TiO2-MWCNT@Inulin was prepared by embedding Inulin (a biopolymer extracted from Allium sativum L.) with TiO2 and MWCNTs. The morphology of the prepared nanocomposite was characterized by High Resolution transmission electron microscopy (HRTEM). Cholesterol oxidase (ChOx) enzyme was then immobilized into the nanocomposite and the immobilization was examined by UV-vis and FT-IR spectral studies. The ChOx immobilized nanocomposite was integrated into carbon paste (CP) matrix to prepare the working electrode for the sensing of cholesterol. Electrochemical characterization of the modified CP/TiO2-MWCNT@Inulin/ChOx electrode was done by cyclic voltammetric (CV) and electrochemical impedance spectroscopic (EIS) studies. Differential pulse voltammetric (DPV) studies were carried out to determine the concentration of cholesterol at the interface of the newly fabricated electrode. The fabricated electrode demonstrated a linear range from 83 μM to 14.28 mM, low limit of detection (35 μM), good sensitivity (21.26 μA mM-1 cm-2), low Km (0.49 mM), high stability (120 days) and good selectivity. The presence of Inulin biopolymer played a vital role in attaching ChOx enzyme firmly to the nanocomposite thereby enhancing the stability and electron transfer efficiency of the electrode. The analysis of product that was formed within the electrochemical cell during the electrochemical oxidation of cholesterol was performed by using sodium nitroprusside. This resulted in a deep purple coloured solution which suggested the electrochemical conversion of cholesterol to cholestenone. The practical applicability of the fabricated electrode was also assessed by the determination of cholesterol in spiked blood serum and milk samples.
-
Immobilization of Horseradish Peroxidase on O-carboxymethylated Chitosan/sol–gel Matrix
Qin Xu,Chun Mao,Ni-Na Liu,Jun-Jie Zhu,Jian Shen
DOI: https://doi.org/10.1016/j.reactfunctpolym.2005.11.015
2006-01-01
Abstract:A water-soluble chitosan derivation O-carboxymethyl chitosan (CMCS) was developed for the efficient immobilization of horseradish peroxidase (HRP) to construct a H2O2 biosensor. Fourier Transform Infrared (FT-IR) spectrophotometer, Atomic Force Microscope (AFM) and electrochemical method were used to characterize the biosensor. The biosensor was used to determine hydrogen peroxide (H2O2) quantitatively in the presence of methylene blue which was used as a mediator to transfer electrons between the electrode and HRP. It offered a linear range of 2.0×10−6–3.7×10−5 and 4.2×10−5–4.57×10−4M, with a detection limit of 5.32×10−7M estimated at a signal-to-noise ration of 3. The apparent Michaelis–Menten constant (KMapp) of the biosensor was 3.544×10−5M.