Three Methods for Monitoring Blood Phenotype Chimera Caused by Hematopoietic Stem Cell Transplantation Recipients with Incompatible ABO Group

LI Gui-ning,LIU Feng,MAO Xiao-lu,HU Li-hua
DOI: https://doi.org/10.13602/j.cnki.jcls.2011.06.021
2011-01-01
Abstract:Objective To evaluate the application of 3 monitoring methods in blood phenotyping for hematopoietic stem cell transplantation(HSCT) recipients with incompatible ABO and conduct the security of transfusion.Methods The antigens of blood group and corresponding antibodies of 24 HSCT recipients with incompatible ABO group were monitored by tube test with saline medium,ABO micro-column gel test and LISS/Coombs card test.Results Both ABO micro-column gel test and tube test were capable to find the red blood cells derived from donors in the first detection,however the ABO micro-column gel test could monitor the chimera from whether major or minor incompatibility.The interpretation of LISS card was difficult to analyze in the patients with positive direct anti-globulin test(DAT),however LISS card showed available to monitor IgG anti-A and(or) anti-B,which usually disappeared later than IgM antibody during the tube test.Donor-derived red cell was first detected in the 36 day and the 20 day in major and minor group respectively.The required time of complete conversion of donor blood group was from 11 to 22 weeks in major group and 10 to 13 weeks in minor group.Conclusion ABO micro-column gel test should be very useful in blood phenotyping for ABO-incompatible HSCT recipients.It is advised that the monitoring of IgG antibody should be detected following disappearance of IgM antibody for major incompatible HSCT.