Development of a dual-detector X-ray imaging system for phase retrieval study

Fanbo Meng,Aimin Yan,Ge Zhou,Xizeng Wu,Hong Liu
DOI: https://doi.org/10.1016/j.nimb.2006.11.075
2007-01-01
Abstract:Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two detectors, respectively and the imaging quality of phantoms. Preliminary results showed that the system is capable of phase X-ray imaging and quantitative phase retrieval.
What problem does this paper attempt to address?