Two-Dimensional LDV Measurement, Modeling, and Optimal Design of Rectangular Primary Settling Tanks

Baicang Liu,Jun Ma,Lin Luo,Yuhua Bai,Shutao Wang,Jing Zhang
DOI: https://doi.org/10.1061/(ASCE)EE.1943-7870.0000186
2010-01-01
Abstract:To optimize the design parameters of rectangular primary settling tanks, we used two-dimensional laser Doppler velocimetry (2D LDV) to conduct flow field measurements in five cases and used a previous model to simulate the flow field. The relative baffle submergence height and the ratio of tank length to height were optimized in a low suspended solid (LSS) concentration (LSS <150-200 mg/L). The experimental and simulation results show that a large recirculation zone exists behind the reaction baffle and the flow magnitude is small in the recirculation region; the length of recirculation increases with an increasing flow rate; the length of recirculation increases as the depth of the submerged reaction baffle increases; and the variation of the reaction baffle height can affect the flow field more significantly than does the variation of the flow rate. We also determined that to reach a higher removal rate and to optimize the area dimensions of a sedimentation tank, a length-to-height design ratio between 8 and 12 is optimal.
What problem does this paper attempt to address?