Quality Evaluation of Flos Lonicerae Through a Simultaneous Determination of Seven Saponins by HPLC with ELSD.

XY Chai,SL Li,P Li
DOI: https://doi.org/10.1016/j.chroma.2005.02.031
IF: 4.601
2005-01-01
Journal of Chromatography A
Abstract:A new HPLC coupled with evaporative light scattering detection (ELSD) method has been developed for the simultaneous quantitative determination of seven major saponins, namely macranthoidin B (1), macranthoidin A (2), dipsacoside B (3), hederagenin-28-O-β-d-glucopyranosyl(6→1)-O-β-d-glucopyranosyl ester (4), macranthoside B (5), macranthoside A (6), and hederagenin-3-O-α-l-arabinopyranosyl(2→1)-O-α-l-rhamnopyranoside (7) in Flos Lonicerae, a commonly used traditional Chinese medicine (TCM) herb. Simultaneous separation of these seven saponins was achieved on a C18 analytical column. The mobile phase consisted of (A) acetonitrile–acetic acid (95:0.5) and (B) 0.5% aqueous acetic acid using a gradient elution of 29%A at 0–10min, 29–46%A at 10–25min and 46%A at 25–30min. The drift tube temperature of ELSD was set at 106°C, and with the nitrogen flow-rate of 2.6l/min. All calibration curves showed good linear regression (r2>0.9922) within test ranges. This method showed good reproducibility for the quantification of these seven saponins in Flos Lonicerae with intra- and inter-day variations of less than 3.0% and 6.0%, respectively. The validated method was successfully applied to quantify seven saponins in five sources of Flos Lonicerae, which provides a new basis of overall assessment on quality of Flos Lonicerae.
What problem does this paper attempt to address?