Research on Stabilization of Induction Motor Speed Sensorless Control System in Low Speed Regenerating Mode

DENG Xin,LUO Hui,WANG Qing-yi,ZHAO Jin,WAN Shu-yun
DOI: https://doi.org/10.15934/j.cnki.micromotors.2009.01.006
2009-01-01
Abstract:The speed observing method based on full order observer has been widely applied in speed sensorless vector control system for its simple,small computation and immunity to the influence of pure integration.The induction as the reference model and a full order induction model as the adjusting model,the comparison between the actual and estimated stator current led to the adaptive signal,and the adapting law was designed according to the Popov stabilization theory or Lyapunov stabilization criterion.But an instability region existed in low speed regenerating mode.The cause was analyzed and the instability area was shown.An improved method was proposed according to the current error vector locus,which stabilized the induction motor in low speed regenerating mode by modifying the projection of current error locus in estimated rotor flux.The method was easy to implement and robust to motor parameters.The simulation results showed that the method could cancel the instability area and the motor could run stably in all modes.It had some application value.