HPLC Determination of Gentiana Gentiopicrin Content and Pharmacokinetic Study

叶莉,蒋袁絮,马学琴,李迎秋,高亦珑
DOI: https://doi.org/10.3969/j.issn.1001-5949.2009.12.012
2009-01-01
Abstract:Objective To establish a HPLC method for the determination of gentiopicrin in rabbits plasma and to investigate the pharmacokinetics of gentiopicrin in gentiana.Methods The analysis was performed on a SHIM-PACK VP-ODS column (150mm×4.6mm,5μm ).The plasma samples were collected after intravenous administration of the gentiana macrop hyllain rabbits.The concentrations of gentiopicrin in p lasma were measured by HPLC method and the pharmacokinetic parameters were calculated by DAS.ResultsThe calibration curve was linear over the range of 0.683μg/ml—136.6μg/ml (r=0.9995) and the quantitative limit was 0.0342μg/ml.The intra and inter assay coefficient of variation were less than 10 % at all levels.The recoveries were 89.8%—101.4%.The plasma concentration time course followed 3 compartment open model and its main pharmacokinetic parameters were as follows:Tmax=0.083h,Cmax=45.1mg/L,V=1.312L/kg,CL=0.761 L/(h·kg),t1/2 = 1.195h,AUC(0-∞)=30.78mg/(L·h).Conclusion This method is sensitive and stable.It is suitable for the pharmacokinetic study of gentiopicrin in gentiana.
What problem does this paper attempt to address?