Content Determination of Baicalin in Maozhiqing Oral Liquid by High Performance Liquid Chromatography Method

LIU Qun-sheng,LIU Shi-jie,HU Shu-ping,LIU Tong-xiang
DOI: https://doi.org/10.3969/j.issn.1000-2219.2011.05.023
2011-01-01
Abstract:Objective To establish a method for content determination of baicalin in Maozhiqing Oral Liquid,a Chinese minority traditional medicine.Methods The Venusil MP C18 column(4.6 mm×250 mm,5 μm) was used,the mobile phase was methanol-water-phosphoric acid(60∶40∶0.2),the flow rate was 1.0 ml/min,the detection wavelength was 280 nm.Results The sample size of Baicalin had a good linear relationship with the peak area within the range of 0.5~3.0 μg with an regression equation being Y=3.00×106 X-415 373(r=0.999 6).The average recovery was 103.0%,and the relative standard deviation was 1.117%.Conclusion The established method of high performance liquid chromatography can be used for quality control of Maozhiqing Oral Liduid because of its simplicity,accuracy,high sensitivity,and good separation.
What problem does this paper attempt to address?