Practical method for calculating effective length coefficient for pillar of main frame of steel arc gates

SHEN Yong-kang,WANG Zheng-zhong,SHAO Jian-hua
DOI: https://doi.org/10.3880/j.issn.1006-7647.2006.04.018
2006-01-01
Abstract:According to an analysis of shortcomings of the pillar stability design method for steel arc gates currently used and the revised Code for Design of Steel Structure GB50017-2003,a practical method for calculation of the effective length coefficient for the pillar of main frame of arc gates was proposed by use of the energy method and selection of a rational deflection function.The method is simple and accurate in computation,clear in physical conception,and convenient for engineering design.
What problem does this paper attempt to address?