Experimental study on fire resistance behaviors of prefabricated composite thermal insulation walls
Xiaojun Zhu,Xiangmin Li,Jian Yang,Shuting Liang,Shaolin Wei,Qingfeng Xu
DOI: https://doi.org/10.3969/j.issn.1001-0505.2017.06.020
2017-01-01
Abstract:To investigate the fire resistance behaviors of the prefabricated composite thermal insulation wall which is composed of inner and outer concrete wythes,different types of insulation boards and steel sleeve connectors.Four prefabricated composite thermal insulation walls subjected to the fire exposure on one side were tested.The thermal insulation properties of different insulation materials and insulation layer thicknesses were analyzed and compared based on the measured characteristics of the temperature field distributions of the walls.Besides,the failure process of the specimens was observed,and the relationship between the out-of-plane displacement and time was compared.The damages of different thermal insulation materials were analyzed by the drilling-core tests.The experimental results show that the maximum lateral deformation of the walls increases with the fire exposure time;when the axial compression ratio is 0.2,the deflection decreases;the lateral deformations of the two walls with different thicknesses of EPS (expandable polystyrene) boards (40 or 60 mm) are almost the same.Compared with the EPS board,the lateral deformations of walls using the XPS (extruded polystyrene) board are smaller.The distribution of the temperature field along the thickness is nonlinear,and the temperature of the unexposed side is less than 100 ℃,much lower than that of the exposed side.The drilling-core test shows that the core from the exposed side is reddish brown,and both the EPS board and XPS board are in the melt state.