Influence of the Permeability of External Thermal Insulation on Concrete Wall Carbonization

Wen XUE,Xuehan SHEN,Jianguo DAI,Weiliang JIN
DOI: https://doi.org/10.3969/j.issn.1001-702x.2009.08.015
2009-01-01
Abstract:In this contribution,several kinds of external wall external thermal insulation systems which are being widely used in Japan are studied.Air permeability tests of these external thermal insulation systems and accelerated carbonization tests of concrete protected by them are performed.Based on the indoor and on-site carbonization testing results,the extruded polystyrene system has relatively lower permeability.When in combination with the grouting construction method,it can effectively prevent concrete from carbonization.It is concluded that when the air permeating coefficient of the external insulation system is larger than 10-4 cm4(/N·s) ,it cannot prevent concrete from carbonization.
What problem does this paper attempt to address?