Abstract:Objective: To study the corrosion resistance of pure titanium by electrochemical methods in simulated body fluid or F-containing simulated body fluid.Methods: Polarization curves and electrochemical impedance spectrum in electrochemical test solution were examined by electrochemical methods.Electrochemical test solution system is divided into two groups,simulated body fluid group or F-containing simulated body fluid group.The experimental contents include polarization curves and electrochemical impedance measurements.Results: The difference of the self-corrosion potential between two groups was not significant(P>0.05).Self-corrosion current density of pure titanium increased significantly(P<0.05),and electrochemical impedance reduced significantly(P<0.001) in F-containing simulated body fluid compared to in simulated body fluid.Conclusion: Fluoride ions decrease the corrosion resistance of pure titanium.