Study on Optimization of Biological Filter Bed Thickness for Removal of Iron and Manganese

Dong LI,Jie ZHANG,Yan-ping ZHANG,Hong-tao WANG
DOI: https://doi.org/10.3321/j.issn:1000-4602.2007.13.025
2007-01-01
Abstract:The thickness of the biological filter bed is important for removal efficiencies of iron and manganese,and the groundwater quality is one of important factors to decide the thickness of the filter bed.The lab-scale experiments show that the feasible thickness is different for the groundwater with different concentration of Fe2+ and Mn2+.The full-scale experiments prove this and show that the thickness of the filter bed ranges from 900 to 1 000 mm for the groundwater with low concentration of Fe2+ and Mn2+.It should be increased to a range of 1 000 to 1 300 mm for the groundwater with high concentration of Fe2+ and Mn2+.
What problem does this paper attempt to address?