Application of center of gravity method in multiple linear CCD detection Scheme

GUO Xiao-jun,GU Yong-gang,XING Xiao-zheng
DOI: https://doi.org/10.3969/j.issn.1001-3997.2008.03.031
2008-01-01
Abstract:It introduces the stability of test system that multiple linear CCD to detect the muti-object in Polar coordinates and the situation of the test system construction.This experiment system includes several parts as follows:a main control computer,multiple linear CCD,a precision rotating platform,scan girder,plane platform,lamp-house,and the self-design control programs.The light center of gravity method is applied to processing optic fiber exited spot signal.Tests on the light point coordinates indicate dynamic and static standard deviation is 0.58μm and 0.32μm when excursion 0.05mm everytime.The stability of system is deal.The result of experiment show that the center of gravity method is the best one to calibrate opposition of signal and has characteristics of stability.