An automatic microturbidostat for bacterial culture at constant density

Xianjia Luo,Kangyang Shen,Chunxiong Luo,Hang Ji,Qi Ouyang,Yong Chen
DOI: https://doi.org/10.1007/s10544-010-9406-5
2010-01-01
Biomedical Microdevices
Abstract:We have developed a microturbidostat for long time bacterial culture at constant density controlled by optical detection and integrated pneumatic valves. The device was fabricated by multilayer soft lithography and in-situ formation of an agarose filter. The culture chamber of bacteria was connected in one side to a single bacterial input-output channel and in another side to a nutrient channel in which the agarose filter was formed to ensure the diffusion of nutrients and metabolites without bacterial loss. The bacterial number in the culture chamber was determined by measuring the fluorescence intensity of GFP proteins of the bacteria and the redundant bacteria could be exported automatically through the input-output channel with integrated micro-valves. In order to optimize the operation performance, we investigated the bacterial exportation efficiency with different input-output channel widths. As expected, the bacterial sorting coefficient was proportional to the input-output channel width. The results also showed that with a 20 µm channel-width, a long time culture was possible with a constant bacterial number in the chamber in the range from 400 to 700.
What problem does this paper attempt to address?