A Novel Space Vector Control Strategy of Four-leg Three-level Shunt Active Power Filter

LE Jian,JIANG Qi-rong,HAN Ying-duo
DOI: https://doi.org/10.3321/j.issn:0258-8013.2006.14.011
2006-01-01
Abstract:A novel space vector control strategy is proposed for four-leg three-level shunt active power filter(APF). Based on the reference voltage decomposition, the complicated switching states selection problem is simplified into a simple two-level space vector control problem and a simple three-level switching state selection problem. Thus the complicated calculating problem of present strategies is resolved. This strategy needs fewer input data, and is very easy to be implemented by the existing hardware. The simulation results of an example show that the proposed strategy has well control effects and can be used in practice.
What problem does this paper attempt to address?