Water-vapor Continuum Absorption in the 800–1250cm−1 Spectral Region at Temperatures from 311 to 363K

Yu. I. Baranov,W. J. Lafferty,Q. Ma,R. H. Tipping
DOI: https://doi.org/10.1016/j.jqsrt.2008.03.004
IF: 2.342
2008-01-01
Journal of Quantitative Spectroscopy and Radiative Transfer
Abstract:About 200 pure water-vapor spectra covering the region from 800 to 3500cm−1 were recorded with resolution of 0.1cm−1 at temperatures 311, 318, 325, 339, 352, and 363K using a 2m base White cell coupled to the BOMEM DA3.002 FTIR spectrometer. The water-vapor pressure varied from 28 to 151mbar (21–113Torr). Under these conditions, the continuum absorbance is quite measurable with the available path lengths up to 116m. A program was developed for spectral processing that calculates, fits, and removes ro-vibrational structure from the spectrum. The spectra obtained were used to retrieve averaged and smoothed binary absorption coefficients over the region from 800 to 1250cm−1. Our continuum data extrapolated to room temperature are in reasonable agreement with the MT_CKD continuum model. But at higher temperatures the MT_CKD model provides very low values, which are up to 50% less than those experimentally measured.